An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size
This study aims to assess the accuracy of CT imaging in estimating intraocular foreign body (IOFB) size by comparing pre-operative radiological measurements with post-surgical dimensions. A retrospective review of 12 cases over 9 years at a UK tertiary centre. IOFB size on CT imaging was compared with post-surgical measurements. Soft tissue window CT overestimated IOFB size (p=0.025). Bone window CT was more accurate but still varied, with one-third differing by>50% to definitive size. We conclude that caution is needed in CT-based IOFB size estimation. Plain radiographs may provide additional accuracy.
Authors
- Tarini Ratneswaren (ORCID: https://orcid.org/0000-0002-1065-1291)
- Martin P. Snead (ORCID: https://orcid.org/0000-0003-0042-8659)
- Hrishikesh Kaza
- Kujani Wanniarachchi
- Arabella Poulson
- Antoine Safi
Institutions
- University of Cambridge (GB)
- Whipps Cross University Hospital (GB)
- National Hospital for Neurology and Neurosurgery (GB)
- University College London (GB)
Publication Details
- Journal
- British Journal of Ophthalmology
- Published
- 2025-06-30
- DOI
- https://doi.org/10.1136/bjo-2025-327245
- Primary Topic
- Traumatic Ocular and Foreign Body Injuries
- Type
- article
- Field-Weighted Citation Impact
- 0.00