Mechanical and Hemocompatibility Assessment of Selected Technologies for Prosthesis Connection with the Outflow Cannula Graft of the RH PED® Pediatric Pulsatile Pump for Heart Support

<b>Background:</b> Heart failure in pediatric patients remains a major cause of morbidity and mortality, often associated with congenital heart defects and cardiomyopathies. Mechanical circulatory support (MCS) devices have emerged as critical therapeutic options, particularly as bridges to transplantation or recovery. The complexity of their use in children necessitates highly specialized solutions. This study aimed to evaluate the quality and performance of selected connection technologies between prosthetic vascular grafts and the outflow cannula of the Religa Heart PED<sup>®</sup> pediatric pulsatile pump, with a focus on tightness, surface smoothness, and structural integrity. <b>Methods:</b> Mechanical testing was conducted on various connection types, including static tensile strength and long-term durability under pulsatile flow conditions with biological fluid analogs. Macro and microscopic evaluations assessed the surface quality and potential thrombogenic risks, biological testing encompassed permeability analysis in static and dynamic settings, and hemocompatibility was determined by acute thrombogenicity. Additionally, in vivo observations in a large animal model were used for final qualitative validation. <b>Results:</b> All connection types demonstrated sufficient mechanical strength, with no structural degradation or leakage observed in any samples following long-term testing. Thrombus formation was absent in adhesive connections with Dacron and polytetrafluoroethylene (PTFE) grafts but was observed in the mechanical connection with the PTFE prosthesis. In addition, in vivo studies confirmed the tightness, hemocompatibility, and mechanical stability of the adhesive connection with the Dacron prosthesis. <b>Conclusions:</b> The adhesive connection between the outflow cannula and a Dacron prosthesis demonstrated superior mechanical and biological performance, including resistance to thrombogenesis and hemolysis, as well as stable integration under in vivo conditions. This solution shows high potential for safe application in the Religa Heart PED<sup>®</sup> system.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-06-30
DOI
https://doi.org/10.3390/jcm14134621
Citations
1
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical and Hemocompatibility Assessment of Selected Technologies for Prosthesis Connection with the Outflow Cannula Graft of the RH PED® Pediatric Pulsatile Pump for Heart Support

Maciej Gawlikowski, Artur Kapis, Klaudia Cholewa, Karolina Goldsztajn et al.
1 citations
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
0.67
article

Mechanical and Hemocompatibility Assessment of Selected Technologies for Prosthesis Connection with the Outflow Cannula Graft of the RH PED® Pediatric Pulsatile Pump for Heart Support

Maciej Gawlikowski, Artur Kapis, Klaudia Cholewa, Karolina Goldsztajn, Przemysław Kurtyka, Karolina Janiczak, W. Walke, Agnieszka Szuber-Dynia, Mateusz Janecki
article en
1 citations

Abstract

<b>Background:</b> Heart failure in pediatric patients remains a major cause of morbidity and mortality, often associated with congenital heart defects and cardiomyopathies. Mechanical circulatory support (MCS) devices have emerged as critical therapeutic options, particularly as bridges to transplantation or recovery. The complexity of their use in children necessitates highly specialized solutions. This study aimed to evaluate the quality and performance of selected connection technologies between prosthetic vascular grafts and the outflow cannula of the Religa Heart PED<sup>®</sup> pediatric pulsatile pump, with a focus on tightness, surface smoothness, and structural integrity. <b>Methods:</b> Mechanical testing was conducted on various connection types, including static tensile strength and long-term durability under pulsatile flow conditions with biological fluid analogs. Macro and microscopic evaluations assessed the surface quality and potential thrombogenic risks, biological testing encompassed permeability analysis in static and dynamic settings, and hemocompatibility was determined by acute thrombogenicity. Additionally, in vivo observations in a large animal model were used for final qualitative validation. <b>Results:</b> All connection types demonstrated sufficient mechanical strength, with no structural degradation or leakage observed in any samples following long-term testing. Thrombus formation was absent in adhesive connections with Dacron and polytetrafluoroethylene (PTFE) grafts but was observed in the mechanical connection with the PTFE prosthesis. In addition, in vivo studies confirmed the tightness, hemocompatibility, and mechanical stability of the adhesive connection with the Dacron prosthesis. <b>Conclusions:</b> The adhesive connection between the outflow cannula and a Dacron prosthesis demonstrated superior mechanical and biological performance, including resistance to thrombogenesis and hemolysis, as well as stable integration under in vivo conditions. This solution shows high potential for safe application in the Religa Heart PED<sup>®</sup> system.

Journal of Clinical MedicineVol. 14(13)
Silesian University of Technology (PL), Foundation of Cardiac Surgery Development (PL)
National Center for Research and Development, Ministry of Science and Higher Education of the Russian Federation
Good health and well-being
Openalex Percentile: Top 30%
Mechanical Circulatory Support Devices
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.