Deep-Learning Based Wearable 8-Channel sEMG Biometrics Modality for User's Verification

Recently, deep learning algorithms have gained prominence for their capacity to learn in diverse applications. However, in electromyography (EMG)-based biometrics, deep learning has not been widely involved, due to the extensive effort required to generate large databases. In this paper, data augmentation is utilized to expand a database, in order to reduce the data collection effort. A Convolutional Neural Network (CNN) is employed to accurately learn user characteristics within an EMG-based biometric system, with the SqueezeNet architecture chosen for its faster training time and reduced parameter requirements. Wavelet Transforms are applied to generate scalograms of the EMG signals. The system is evaluated in terms of testing accuracy, False Acceptance Rate, and False Rejection Rate. A classifier accuracy of 98.31% has been achieved.

Authors

Institutions

Publication Details

Published
2025-05-14
DOI
https://doi.org/10.1109/biosmart66413.2025.11046032
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep-Learning Based Wearable 8-Channel sEMG Biometrics Modality for User's Verification

A. Naït-Ali, Samer Al Kork, Karim Youssef, Sherif Said
Muscle activation and electromyography studies
article

Deep-Learning Based Wearable 8-Channel sEMG Biometrics Modality for User's Verification

A. Naït-Ali, Samer Al Kork, Karim Youssef, Sherif Said
article en

Abstract

Recently, deep learning algorithms have gained prominence for their capacity to learn in diverse applications. However, in electromyography (EMG)-based biometrics, deep learning has not been widely involved, due to the extensive effort required to generate large databases. In this paper, data augmentation is utilized to expand a database, in order to reduce the data collection effort. A Convolutional Neural Network (CNN) is employed to accurately learn user characteristics within an EMG-based biometric system, with the SqueezeNet architecture chosen for its faster training time and reduced parameter requirements. Wavelet Transforms are applied to generate scalograms of the EMG signals. The system is evaluated in terms of testing accuracy, False Acceptance Rate, and False Rejection Rate. A classifier accuracy of 98.31% has been achieved.

Université Paris-Est Créteil (FR), Paris-Est Sup (FR), American University of the Middle East (KW)
Openalex Percentile: Top 86%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deep-Learning Based Wearable 8-Channel sEMG Biometrics Modality for User's Verification — A. Naït-Ali, Samer Al Kork, et al. · (2025) | TGRS Research Map | TGRS