Novel Deep Learning Model to Estimate Knee Flexion and Adduction Moments With Wearable IMUs During Treadmill and Overground Walking

A major issue after total knee replacement (TKR) surgery is asymmetric gait kinetics, which increases knee loads on the non-operated knee. This imbalance accelerates osteoarthritis (OA) progression, often leading to a second contralateral TKR. There is a clear need for an advanced wearable system with multiple sensors to accurately estimate gait kinetics in natural environments. This study aims to develop a machine learning framework that exclusively uses wearable inertial measurement units (IMUs) during overground and treadmill walking to estimate knee flexion moment (KFM) and knee adduction moment (KAM), significant biomechanical factors linked to OA. We introduce a novel deep learning model that combines a Long Short-Term Memory (LSTM)-based Autoencoder and Variational Gaussian Process (VGP) to estimate the mean and uncertainty region of the KAM and KFM. Seventeen healthy participants performed treadmill walking trials, while a separate group of seventeen healthy participants performed overground walking trials for model training and validation. Results demonstrated Root Mean Square Errors (RMSE) of 0.49%BW$\cdot$BH (body weight × body height) and 0.73%BW$\cdot$BH for KAM and KFM, respectively, during treadmill walking and 0.74%BW$\cdot$BH and 0.49%BW$\cdot$BH for KAM and KFM respectively during overground walking, which is more accurate than existing approaches. The proposed model with wearable IMUs could enable knee health monitoring and rehabilitation for these key biomechanical factors linked to the progression of knee joint pathologies outside of traditional biomechanical laboratories with large, tethered equipment and into clinics, hospitals, and the community.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-06-30
DOI
https://doi.org/10.1109/jbhi.2025.3584389
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Deep Learning Model to Estimate Knee Flexion and Adduction Moments With Wearable IMUs During Treadmill and Overground Walking

Shani Batcir, Kfir Y. Levy, Tian Tan, A. Fischer et al.
1 citations
IEEE Journal of Biomedical and Health Informatics
Muscle activation and electromyography studies
0.67
article

Novel Deep Learning Model to Estimate Knee Flexion and Adduction Moments With Wearable IMUs During Treadmill and Overground Walking

Shani Batcir, Kfir Y. Levy, Tian Tan, A. Fischer, Peter B. Shull, Alon Sabaty, Adi Fishman
article en
1 citations

Abstract

A major issue after total knee replacement (TKR) surgery is asymmetric gait kinetics, which increases knee loads on the non-operated knee. This imbalance accelerates osteoarthritis (OA) progression, often leading to a second contralateral TKR. There is a clear need for an advanced wearable system with multiple sensors to accurately estimate gait kinetics in natural environments. This study aims to develop a machine learning framework that exclusively uses wearable inertial measurement units (IMUs) during overground and treadmill walking to estimate knee flexion moment (KFM) and knee adduction moment (KAM), significant biomechanical factors linked to OA. We introduce a novel deep learning model that combines a Long Short-Term Memory (LSTM)-based Autoencoder and Variational Gaussian Process (VGP) to estimate the mean and uncertainty region of the KAM and KFM. Seventeen healthy participants performed treadmill walking trials, while a separate group of seventeen healthy participants performed overground walking trials for model training and validation. Results demonstrated Root Mean Square Errors (RMSE) of 0.49%BW$\cdot$BH (body weight × body height) and 0.73%BW$\cdot$BH for KAM and KFM, respectively, during treadmill walking and 0.74%BW$\cdot$BH and 0.49%BW$\cdot$BH for KAM and KFM respectively during overground walking, which is more accurate than existing approaches. The proposed model with wearable IMUs could enable knee health monitoring and rehabilitation for these key biomechanical factors linked to the progression of knee joint pathologies outside of traditional biomechanical laboratories with large, tethered equipment and into clinics, hospitals, and the community.

IEEE Journal of Biomedical and Health InformaticsVol. 30(1)
Technion – Israel Institute of Technology (IL), Shanghai Jiao Tong University (CN), Stanford University (US)
Gender equality
Openalex Percentile: Top 30%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.