Determination of Irbesartan in Pharmaceutical Preparations by HPLC

In this study, a high-performance liquid chromatography (HPLC) method was developed to analyze irbesartan in both pure and pharmaceutical formulations. The mobile phase consisted of an acetonitrile-1.0 mM potassium dihydrogen phosphate solution (30:70, v/v), adjusted to pH 3.0 with phosphoric acid. The analysis was performed using an Ace C18 column, and a UV detector was employed to monitor the eluent at 220 nm. With a flow rate of 1.0 mL min-1, the analysis was completed in under 6 minutes. The calibration curve was linear across the concentration range of 0.10-5.0 μg mL-1. The accuracy of the method (relative error) for irbesartan was better than 2.67%, and the intra- and inter-day precision values were below 3.23%. The mean recovery of irbesartan in pharmaceutical formulations was 101.4%. The limits of detection and quantitation were found to be 0.03 and 0.10 μg mL-1, respectively. Furthermore, the method proved to be effective for quantifying the drug and confirming the consistency of the formulation content in commercial irbesartan dosage forms.

Authors

Institutions

Publication Details

Journal
Cumhuriyet Science Journal
Published
2025-06-30
DOI
https://doi.org/10.17776/csj.1485381
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Irbesartan in Pharmaceutical Preparations by HPLC

Bilal Yılmaz
Cumhuriyet Science Journal
Analytical Methods in Pharmaceuticals
article

Determination of Irbesartan in Pharmaceutical Preparations by HPLC

Bilal Yılmaz
article en

Abstract

In this study, a high-performance liquid chromatography (HPLC) method was developed to analyze irbesartan in both pure and pharmaceutical formulations. The mobile phase consisted of an acetonitrile-1.0 mM potassium dihydrogen phosphate solution (30:70, v/v), adjusted to pH 3.0 with phosphoric acid. The analysis was performed using an Ace C18 column, and a UV detector was employed to monitor the eluent at 220 nm. With a flow rate of 1.0 mL min-1, the analysis was completed in under 6 minutes. The calibration curve was linear across the concentration range of 0.10-5.0 μg mL-1. The accuracy of the method (relative error) for irbesartan was better than 2.67%, and the intra- and inter-day precision values were below 3.23%. The mean recovery of irbesartan in pharmaceutical formulations was 101.4%. The limits of detection and quantitation were found to be 0.03 and 0.10 μg mL-1, respectively. Furthermore, the method proved to be effective for quantifying the drug and confirming the consistency of the formulation content in commercial irbesartan dosage forms.

Cumhuriyet Science JournalVol. 46(2)
Atatürk University (TR)
Openalex Percentile: Top 83%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.