In-situ Measurement of the TCR of Pt for Long-term Stability of Thermal Conductivity Hydrogen Sensor

In this study, we developed an in-situ measurement technique for the temperature coefficient of resistance (TCR) of Pt thin film. Pt thin film was exposed to high temperature in the electric furnace at 400°C to evaluate the sintering time dependence of TCR and specific resistance of Pt. During the long-term sintering of Pt thin films at 400°C, it was confirmed that the TCR of the Pt thin films gradually increased, while the specific resistance gradually decreased. Since the specific resistance of the Pt thin film almost linearly decreased with the increase in TCR, TCR can be deduced by measuring the resistance of the Pt thin film. By using the deduced TCR value, it becomes possible to accurately measure the temperature of the micro-hotplate, thereby maintaining the accuracy of the thermal conductivity gas sensor over a long period.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Sensors and Micromachines
Published
2025-06-30
DOI
https://doi.org/10.1541/ieejsmas.145.165
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
1.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-situ Measurement of the TCR of Pt for Long-term Stability of Thermal Conductivity Hydrogen Sensor

Shunsuke Akasaka, Isaku Kanno, Maiko Hatano
1 citations
IEEJ Transactions on Sensors and Micromachines
Sensor Technology and Measurement Systems
1.49
article

In-situ Measurement of the TCR of Pt for Long-term Stability of Thermal Conductivity Hydrogen Sensor

Shunsuke Akasaka, Isaku Kanno, Maiko Hatano
article en
1 citations

Abstract

In this study, we developed an in-situ measurement technique for the temperature coefficient of resistance (TCR) of Pt thin film. Pt thin film was exposed to high temperature in the electric furnace at 400°C to evaluate the sintering time dependence of TCR and specific resistance of Pt. During the long-term sintering of Pt thin films at 400°C, it was confirmed that the TCR of the Pt thin films gradually increased, while the specific resistance gradually decreased. Since the specific resistance of the Pt thin film almost linearly decreased with the increase in TCR, TCR can be deduced by measuring the resistance of the Pt thin film. By using the deduced TCR value, it becomes possible to accurately measure the temperature of the micro-hotplate, thereby maintaining the accuracy of the thermal conductivity gas sensor over a long period.

IEEJ Transactions on Sensors and MicromachinesVol. 145(7)
Kobe University (JP)
Affordable and clean energy
Openalex Percentile: Top 16%
Sensor Technology and Measurement Systems
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In-situ Measurement of the TCR of Pt for Long-term Stability of Thermal Conductivity Hydrogen Sensor — Shunsuke Akasaka, Isaku Kanno, et al. · IEEJ Transactions on Sensors and Micromachines (2025) | TGRS Research Map | TGRS