A cross-sectional study on the evaluation of laboratory analytical quality performance in a tertiary medical college in Eastern India

Background: Six Sigma is a powerful management tool that can be used in the laboratory to assess the quality of performance in the analytical phase. Aims and Objectives: This study aims to calculate the sigma metrics of 17 biochemistry test analytes over a period of 1 year from January to December 2024. The quality goal index (QGI) is measured for analytes with Sigma metric value <3. The total analytical error observed is compared with the established total allowable error (TEa) guidelines. The root cause analysis, followed by corrective action, will be taken for parameters with poor performance. An appropriate quality control (QC) strategy will be planned for these routine biochemistry tests for quality improvement. Materials and Methods: The daily internal quality control (IQC) and the monthly External quality assessment scheme samples were run for biochemistry analytes. The mean, standard deviation, coefficient of variation, Bias%, Total error observed (TEobs), and Sigma metric were calculated for each IQC level of each analyte. The QGI was measured for analytes with a Sigma value of <3. Results: The Sigma value was highest for direct bilirubin and the lowest for phosphorus. The QGI for analytes with Sigma <3 revealed the underlying cause as inaccuracy. The TEobs was higher than the TEa for albumin, creatinine, phosphorus, and total protein. The root cause analysis demonstrated various reasons for the observed inaccuracy. A QC strategy was designed for the laboratory, based on the guidelines proposed by Westgard and Cooper. Conclusion: This study has demonstrated that Sigma metrics can be used to assess laboratory quality, analyze the cause of low performance, and also design a QC strategy for optimum and better laboratory performance.

Authors

Institutions

Publication Details

Journal
Asian Journal of Medical Sciences
Published
2025-06-30
DOI
https://doi.org/10.71152/ajms.v16i7.4564
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A cross-sectional study on the evaluation of laboratory analytical quality performance in a tertiary medical college in Eastern India

Sayani Chaudhuri
5 links
Asian Journal of Medical Sciences
Quality and Safety in Healthcare
article

A cross-sectional study on the evaluation of laboratory analytical quality performance in a tertiary medical college in Eastern India

Sayani Chaudhuri
article en

Abstract

Background: Six Sigma is a powerful management tool that can be used in the laboratory to assess the quality of performance in the analytical phase. Aims and Objectives: This study aims to calculate the sigma metrics of 17 biochemistry test analytes over a period of 1 year from January to December 2024. The quality goal index (QGI) is measured for analytes with Sigma metric value <3. The total analytical error observed is compared with the established total allowable error (TEa) guidelines. The root cause analysis, followed by corrective action, will be taken for parameters with poor performance. An appropriate quality control (QC) strategy will be planned for these routine biochemistry tests for quality improvement. Materials and Methods: The daily internal quality control (IQC) and the monthly External quality assessment scheme samples were run for biochemistry analytes. The mean, standard deviation, coefficient of variation, Bias%, Total error observed (TEobs), and Sigma metric were calculated for each IQC level of each analyte. The QGI was measured for analytes with a Sigma value of <3. Results: The Sigma value was highest for direct bilirubin and the lowest for phosphorus. The QGI for analytes with Sigma <3 revealed the underlying cause as inaccuracy. The TEobs was higher than the TEa for albumin, creatinine, phosphorus, and total protein. The root cause analysis demonstrated various reasons for the observed inaccuracy. A QC strategy was designed for the laboratory, based on the guidelines proposed by Westgard and Cooper. Conclusion: This study has demonstrated that Sigma metrics can be used to assess laboratory quality, analyze the cause of low performance, and also design a QC strategy for optimum and better laboratory performance.

Asian Journal of Medical SciencesVol. 16(7)
Ramakrishna Mission Vidyamandira (IN)
Openalex Percentile: Top 72%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A cross-sectional study on the evaluation of laboratory analytical quality performance in a tertiary medical college in Eastern India — Sayani Chaudhuri · Asian Journal of Medical Sciences (2025) | TGRS Research Map | TGRS