Left Ventricular Strain Mapping Utilizing Novel Strain Tracking Techniques

The objective of this study was to evaluate the effectiveness and usability of Vevo Strain 2.0 (VS2), a FUJIFILM VisualSonics Inc. software package to assess left ventricular functional parameters from ultrasound images. We hypothesized that VS2 would achieve left ventricle strain values within 20% of Vevo Strain 1.0 (VS1) while providing more physiological information and a better user experience. To achieve this, we evaluated the left ventricular strain of C57Bl/6N adult male mice (n=4) at three surgical timepoints: healthy baseline (prior to surgery), 3 weeks after induction of transverse aortic constriction via microsurgery, and 1 week after releasing the transverse aortic constriction. Strain was evaluated using VS1 and VS2 left ventricular wall motion tracking software of brightness mode ultrasound images in both the short- and long-axis planes. In the short-axis plane, global circumferential strain values were within the 20% threshold between VS1 and VS2 for all animals at all experimental timepoints. In the long-axis plane, approximately ¾ of all the global longitudinal strain values were within the 20% threshold. Further, in both planes, as strain magnitude increased, the differences in strain between VS1 and VS2 decreased, especially in strains greater than 15%. This is likely due to the fact that at small strains, noise and image quality can have a bigger impact on the overall results. From these comparisons, we can conclude that VS2 can accurately track the wall motion of the left ventricle from a short- or long-axis ultrasound image. Additionally, VS2 provided additional information regarding regional strain differences, the capacity to evaluate 4-dimensional strain using multiple views of the same left ventricle, and a more user-friendly interface with which to analyze data. This abstract was presented at the American Physiology Summit 2025 and is only available in HTML format. There is no downloadable file or PDF version. The Physiology editorial board was not involved in the peer review process.

Authors

Institutions

Publication Details

Journal
Physiology
Published
2025-05-01
DOI
https://doi.org/10.1152/physiol.2025.40.s1.1195
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Left Ventricular Strain Mapping Utilizing Novel Strain Tracking Techniques

Pierre Sicard, Elnaz Ghajar-Rahimi, Craig J. Goergen, Kristiina L. Aasa et al.
Physiology
Cardiovascular Function and Risk Factors
article

Left Ventricular Strain Mapping Utilizing Novel Strain Tracking Techniques

Pierre Sicard, Elnaz Ghajar-Rahimi, Craig J. Goergen, Kristiina L. Aasa, Cortland H. Johns, Sarah Burris
article en

Abstract

The objective of this study was to evaluate the effectiveness and usability of Vevo Strain 2.0 (VS2), a FUJIFILM VisualSonics Inc. software package to assess left ventricular functional parameters from ultrasound images. We hypothesized that VS2 would achieve left ventricle strain values within 20% of Vevo Strain 1.0 (VS1) while providing more physiological information and a better user experience. To achieve this, we evaluated the left ventricular strain of C57Bl/6N adult male mice (n=4) at three surgical timepoints: healthy baseline (prior to surgery), 3 weeks after induction of transverse aortic constriction via microsurgery, and 1 week after releasing the transverse aortic constriction. Strain was evaluated using VS1 and VS2 left ventricular wall motion tracking software of brightness mode ultrasound images in both the short- and long-axis planes. In the short-axis plane, global circumferential strain values were within the 20% threshold between VS1 and VS2 for all animals at all experimental timepoints. In the long-axis plane, approximately ¾ of all the global longitudinal strain values were within the 20% threshold. Further, in both planes, as strain magnitude increased, the differences in strain between VS1 and VS2 decreased, especially in strains greater than 15%. This is likely due to the fact that at small strains, noise and image quality can have a bigger impact on the overall results. From these comparisons, we can conclude that VS2 can accurately track the wall motion of the left ventricle from a short- or long-axis ultrasound image. Additionally, VS2 provided additional information regarding regional strain differences, the capacity to evaluate 4-dimensional strain using multiple views of the same left ventricle, and a more user-friendly interface with which to analyze data. This abstract was presented at the American Physiology Summit 2025 and is only available in HTML format. There is no downloadable file or PDF version. The Physiology editorial board was not involved in the peer review process.

PhysiologyVol. 40(S1)
Inserm (FR), Purdue University West Lafayette (US), FujiFilm VisualSonics (Canada) (CA)
Openalex Percentile: Top 74%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.