Power quality disturbance identification based on gated space-time graph neural network

With the increasing scale of power systems, the assurance of power quality is facing unprecedented challenges. To improve the operation quality of the power system, a power quality disturbance identification method is studied and designed. The process uses a graph convolutional neural network as the basis to capture local and global features of the power system network, the fine-grained preference information of the signal is exploited, and the weighted sum is performed to obtain the final perturbation representation result. The experimental results show that in the recall test, the research method has a recall value of 0.328 for the number of disturbances of 1 in the voltage dips scenario, and the recall value increases to 0.491 when the number rises to 11. This indicates that the research method is able to effectively and accurately identify the disturbance information.

Authors

Institutions

Publication Details

Published
2025-06-30
DOI
https://doi.org/10.1117/12.3066801
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power quality disturbance identification based on gated space-time graph neural network

Hancong Huangfu, Yongcai Wang, Muxu Li
Power Systems and Technologies
article

Power quality disturbance identification based on gated space-time graph neural network

Hancong Huangfu, Yongcai Wang, Muxu Li
article en

Abstract

With the increasing scale of power systems, the assurance of power quality is facing unprecedented challenges. To improve the operation quality of the power system, a power quality disturbance identification method is studied and designed. The process uses a graph convolutional neural network as the basis to capture local and global features of the power system network, the fine-grained preference information of the signal is exploited, and the weighted sum is performed to obtain the final perturbation representation result. The experimental results show that in the recall test, the research method has a recall value of 0.328 for the number of disturbances of 1 in the voltage dips scenario, and the recall value increases to 0.491 when the number rises to 11. This indicates that the research method is able to effectively and accurately identify the disturbance information.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.