PERBEDAAN HASIL PEMERIKSAAN HITUNG JUMLAH LEUKOSIT MENGGUNAKAN TABUNG K3EDTA DAN TABUNG MIKRO EDTA DENGAN VOLUME DARAH 0,5 ml

Introduction: The success of a hematology examination is influenced by the examination process, which includes three stages: pre-analytic, analytic, and post-analytic. The volume of blood in the collection process must match the volume indicated on the vacutainer tube. The accuracy of the EDTA to-blood volume ratio greatly affects the examination of leukocyte count. If the ratio of EDTA to blood is incorrect, it will produce inaccurate results. Objective: To determine the differences in the leukocyte count in blood samples collected in K3EDTA tubes with a volume of 0.5 ml versus Micro EDTA tubes with a volume of 0.5 ml. Method: This quantitative research uses cross-sectional methods with a pre-experimental research design, specifically a one shot case study. The research sampel was treated by separating a 0.5 ml sample into a K3EDTA tube and a 0.5 ml sample into a Micro EDTA tube. Results: Examination results from 44 samples showed that the everage leukocyte count in the K3EDTA tube with a blood volume of 0.5 ml was 6.2 (103/ul) and the average leukocyte count in the Micro EDTA tube was 6.3 (103/ul). Statistical testing using the Wilxocon test yielded a p-value of 0.006 (p < 0.05). Discussion: There is a significant difference in the leukocyte count examination results between the K3EDTA tube and the Micro EDTA tube with a blood volume of 0.5 ml. It is crucial to ensure that the blood volume in the vacutainer tube is correct to obtain accurate and reliable analysis results.

Authors

Publication Details

Journal
Masker Medika
Published
2025-06-30
DOI
https://doi.org/10.52523/maskermedika.v13i1.720
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PERBEDAAN HASIL PEMERIKSAAN HITUNG JUMLAH LEUKOSIT MENGGUNAKAN TABUNG K3EDTA DAN TABUNG MIKRO EDTA DENGAN VOLUME DARAH 0,5 ml

Indah Sari
Masker Medika
Clinical Laboratory Practices and Quality Control
article

PERBEDAAN HASIL PEMERIKSAAN HITUNG JUMLAH LEUKOSIT MENGGUNAKAN TABUNG K3EDTA DAN TABUNG MIKRO EDTA DENGAN VOLUME DARAH 0,5 ml

Indah Sari
article en

Abstract

Introduction: The success of a hematology examination is influenced by the examination process, which includes three stages: pre-analytic, analytic, and post-analytic. The volume of blood in the collection process must match the volume indicated on the vacutainer tube. The accuracy of the EDTA to-blood volume ratio greatly affects the examination of leukocyte count. If the ratio of EDTA to blood is incorrect, it will produce inaccurate results. Objective: To determine the differences in the leukocyte count in blood samples collected in K3EDTA tubes with a volume of 0.5 ml versus Micro EDTA tubes with a volume of 0.5 ml. Method: This quantitative research uses cross-sectional methods with a pre-experimental research design, specifically a one shot case study. The research sampel was treated by separating a 0.5 ml sample into a K3EDTA tube and a 0.5 ml sample into a Micro EDTA tube. Results: Examination results from 44 samples showed that the everage leukocyte count in the K3EDTA tube with a blood volume of 0.5 ml was 6.2 (103/ul) and the average leukocyte count in the Micro EDTA tube was 6.3 (103/ul). Statistical testing using the Wilxocon test yielded a p-value of 0.006 (p < 0.05). Discussion: There is a significant difference in the leukocyte count examination results between the K3EDTA tube and the Micro EDTA tube with a blood volume of 0.5 ml. It is crucial to ensure that the blood volume in the vacutainer tube is correct to obtain accurate and reliable analysis results.

Masker MedikaVol. 13(1)
Openalex Percentile: Top 80%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PERBEDAAN HASIL PEMERIKSAAN HITUNG JUMLAH LEUKOSIT MENGGUNAKAN TABUNG K3EDTA DAN TABUNG MIKRO EDTA DENGAN VOLUME DARAH 0,5 ml — Indah Sari · Masker Medika (2025) | TGRS Research Map | TGRS