The effects of twisted strips with different length on heat transfer and pressure drop in concentric heat exchanger

This study investigated the use of twisted strips as passive turbulators to improve heat transfer efficiency in concentric heat exchangers. In the experiments, four different lengths of twisted strips were designed (l = 0.25 m, 0.5 m, 0.75 m, and 1 m) and their performance was evaluated in a system with air and water fluids. The effects of twisted strips on heat transfer and pressure drops are investigated in both parallel and countercurrent flow patterns, and the results are analyzed in terms of Nusselt and Reynolds numbers. The results indicated that tubes using twisted strips achieved significant increases in the heat transfer coefficient compared to straight tubes. The highest increase in heat transfer performance reached 78% when the length of the twisted strip was l/L=1. The Nusselt number increased by a factor of 1.2 to 1.8, depending on the length of the twisted strips. The shortest strip length (l/L=0.25) resulted in the lowest heat transfer performance. However, these improvements were accompanied by significant increases in pressure drop; for full-length strips, the pressure drop increased by nearly 100%. The pressure drop increased slightly as the Reynolds number increased. The swirling flow generated by the twisted ribbons plays an important role in increasing the heat transfer. Despite the increases in pressure drops, the energy loss is negligible compared to the heat transfer gain achieved. In conclusion, the length ratio of the twisted strips significantly affects the thermal performance of the heat exchanger while increasing the pressure losses. These findings demonstrate the effectiveness of twisted strips as passive turbulators.

Authors

Institutions

Publication Details

Journal
Bitlis Eren University Journal of Science and Technology
Published
2025-06-30
DOI
https://doi.org/10.17678/beuscitech.1591461
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effects of twisted strips with different length on heat transfer and pressure drop in concentric heat exchanger

Cengiz Yıldız, Emin El, Zeki Argunhan
Bitlis Eren University Journal of Science and Technology
Heat Transfer and Optimization
article

The effects of twisted strips with different length on heat transfer and pressure drop in concentric heat exchanger

Cengiz Yıldız, Emin El, Zeki Argunhan
article en

Abstract

This study investigated the use of twisted strips as passive turbulators to improve heat transfer efficiency in concentric heat exchangers. In the experiments, four different lengths of twisted strips were designed (l = 0.25 m, 0.5 m, 0.75 m, and 1 m) and their performance was evaluated in a system with air and water fluids. The effects of twisted strips on heat transfer and pressure drops are investigated in both parallel and countercurrent flow patterns, and the results are analyzed in terms of Nusselt and Reynolds numbers. The results indicated that tubes using twisted strips achieved significant increases in the heat transfer coefficient compared to straight tubes. The highest increase in heat transfer performance reached 78% when the length of the twisted strip was l/L=1. The Nusselt number increased by a factor of 1.2 to 1.8, depending on the length of the twisted strips. The shortest strip length (l/L=0.25) resulted in the lowest heat transfer performance. However, these improvements were accompanied by significant increases in pressure drop; for full-length strips, the pressure drop increased by nearly 100%. The pressure drop increased slightly as the Reynolds number increased. The swirling flow generated by the twisted ribbons plays an important role in increasing the heat transfer. Despite the increases in pressure drops, the energy loss is negligible compared to the heat transfer gain achieved. In conclusion, the length ratio of the twisted strips significantly affects the thermal performance of the heat exchanger while increasing the pressure losses. These findings demonstrate the effectiveness of twisted strips as passive turbulators.

Bitlis Eren University Journal of Science and TechnologyVol. 15(1)
Fırat University (TR), Bitlis Eren University (TR)
Openalex Percentile: Top 85%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.