Decoding the cold-cathode flat-panel X-ray source distribution by coded aperture imaging

Different from the conventional X-ray point tube, the cold-cathode flat-panel X-ray source (FPXS) achieved planar integration of tens of thousands of X-ray point sources. However, the X-ray source distribution of the FPXS at the generating plane (Mo target) is unknown and cannot be directly measured, which hinders its practical use. To address this issue, we propose to decompose the X-ray distribution of the FPXS from the aliased projection of a coded mask. The aliased projection was a circular convolution of the source distribution of FPXS and the basic coded mask, which uniquely encodes the FPXS flux. Besides, the maximum-likelihood expectation-maximization (ML-EM) algorithm was derived to reconstruct the source distribution. Both Monte Carlo (MC) simulation and real experiments were conducted to demonstrate the effectiveness of the proposed method. In the real experiments, the X-ray emission shapes formed by placing lead plates on the surface of the anode substrate of two FPXSs were successfully reconstructed by the proposed method. Moreover, knowing and then compensating the non-uniformity distribution of the FPXS is paramount for future novel and practical applications of the X-ray source.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-06-30
DOI
https://doi.org/10.1364/oe.566728
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Decoding the cold-cathode flat-panel X-ray source distribution by coded aperture imaging

Xuanqin Mou, Jun Chen, Guicai Qi, Guifang Shao et al.
Optics Express
Medical Imaging Techniques and Applications
article

Decoding the cold-cathode flat-panel X-ray source distribution by coded aperture imaging

Xuanqin Mou, Jun Chen, Guicai Qi, Guifang Shao, Zengxiang Pan, Wangjiang Wu, Yuan Xu, Song Kang, Yang Chen, Qi Liu, Qing Li, Linghong Zhou, Tiliang Zou
article en

Abstract

Different from the conventional X-ray point tube, the cold-cathode flat-panel X-ray source (FPXS) achieved planar integration of tens of thousands of X-ray point sources. However, the X-ray source distribution of the FPXS at the generating plane (Mo target) is unknown and cannot be directly measured, which hinders its practical use. To address this issue, we propose to decompose the X-ray distribution of the FPXS from the aliased projection of a coded mask. The aliased projection was a circular convolution of the source distribution of FPXS and the basic coded mask, which uniquely encodes the FPXS flux. Besides, the maximum-likelihood expectation-maximization (ML-EM) algorithm was derived to reconstruct the source distribution. Both Monte Carlo (MC) simulation and real experiments were conducted to demonstrate the effectiveness of the proposed method. In the real experiments, the X-ray emission shapes formed by placing lead plates on the surface of the anode substrate of two FPXSs were successfully reconstructed by the proposed method. Moreover, knowing and then compensating the non-uniformity distribution of the FPXS is paramount for future novel and practical applications of the X-ray source.

Optics ExpressVol. 33(15)
Sun Yat-sen University (CN), CM Hospital (KR), Xi'an Jiaotong University (CN), Guangzhou Medical University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 77%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.