MULTIWAVELENGTH PHOTOPLETHYSMOGRAPHY SYSTEM

Photoplethysmography (PPG) is a promising technology for assessing the cardiovascular system's condition due to its ability to analyze changes in blood volume within the microvascular bed. Beyond standard parameters such as heart rate and blood oxygen saturation, the pulse wave shape in PPG signals contains additional valuable information that can be utilized for assessing heart rate variability, arterial stiffness, and blood pressure. However, the successful use of PPG in everyday activities requires reliable acquisition of signals free from saturation, motion artifacts, and other interferences. This study presents a multiwavelength photoplethysmography (MW-PPG) sensor system capable of continuous real-time signal recording. Two types of sensors were developed: a three-wavelength finger PPG sensor utilizing backscattered light and a three-wavelength ear PPG sensor using transmitted light. The system can record up to eight independent signals, and its operation is controlled by a microcontroller managing the power and signal processing subsystems. The software allows for customizable operation settings, including signal amplification modes and LED activation sequences. To evaluate the system's performance, signal quality was analyzed using the Pearson correlation coefficient (PCC). The average PCC values for the finger and ear sensors ranged from 0.973 to 0.995, indicating the high accuracy and reliability of the developed system. The highest PCC values were obtained for the wavelength pair of 660 nm and 940 nm, while lower values were observed for the 568 nm and 660 nm pair due to stronger light absorption by tissues at 568 nm. The results confirm the effectiveness of the proposed MW-PPG system for measuring high-quality physiological signals.

Authors

Institutions

Publication Details

Journal
Bulletin of Kyiv Polytechnic Institute Series Instrument Making
Published
2025-06-28
DOI
https://doi.org/10.20535/1970.69(1).2025.331971
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MULTIWAVELENGTH PHOTOPLETHYSMOGRAPHY SYSTEM

Dmytro Velyhotskyi, С. А. Мамилов, Serhii Duha
Bulletin of Kyiv Polytechnic Institute Series Instrument Making
Non-Invasive Vital Sign Monitoring
article

MULTIWAVELENGTH PHOTOPLETHYSMOGRAPHY SYSTEM

Dmytro Velyhotskyi, С. А. Мамилов, Serhii Duha
article en

Abstract

Photoplethysmography (PPG) is a promising technology for assessing the cardiovascular system's condition due to its ability to analyze changes in blood volume within the microvascular bed. Beyond standard parameters such as heart rate and blood oxygen saturation, the pulse wave shape in PPG signals contains additional valuable information that can be utilized for assessing heart rate variability, arterial stiffness, and blood pressure. However, the successful use of PPG in everyday activities requires reliable acquisition of signals free from saturation, motion artifacts, and other interferences. This study presents a multiwavelength photoplethysmography (MW-PPG) sensor system capable of continuous real-time signal recording. Two types of sensors were developed: a three-wavelength finger PPG sensor utilizing backscattered light and a three-wavelength ear PPG sensor using transmitted light. The system can record up to eight independent signals, and its operation is controlled by a microcontroller managing the power and signal processing subsystems. The software allows for customizable operation settings, including signal amplification modes and LED activation sequences. To evaluate the system's performance, signal quality was analyzed using the Pearson correlation coefficient (PCC). The average PCC values for the finger and ear sensors ranged from 0.973 to 0.995, indicating the high accuracy and reliability of the developed system. The highest PCC values were obtained for the wavelength pair of 660 nm and 940 nm, while lower values were observed for the 568 nm and 660 nm pair due to stronger light absorption by tissues at 568 nm. The results confirm the effectiveness of the proposed MW-PPG system for measuring high-quality physiological signals.

Bulletin of Kyiv Polytechnic Institute Series Instrument Making(69(1))
Twitter (United States) (US)
Openalex Percentile: Top 86%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MULTIWAVELENGTH PHOTOPLETHYSMOGRAPHY SYSTEM — Dmytro Velyhotskyi, С. А. Мамилов, et al. · Bulletin of Kyiv Polytechnic Institute Series Instrument Making (2025) | TGRS Research Map | TGRS