Evaluation of in-plane shear performance of CLT using the asymmetric four-point bending test method and detailed examination of the method

Abstract The use of cross-laminated timber (CLT) and laminated veneer lumber (LVL) in wooden structures including non-residential, tall and large buildings is increasing, even though they might be subjected to important horizontal forces. The asymmetric four-point bending test method, originally used for lumber and glulam, can be used to evaluate the in-plane shear performance of CLT. This test may have led to bending failure in the case of the CLT specimens. In this study, asymmetric four-point bending tests were conducted to evaluate appropriate shear strength and modulus. Span ratio of 0.5–1.0 is recommended for shear failure to occur as the latter is less affected by compression force. The shear strength exhibited a positive correlation with the ratio of the perpendicular layer, suggesting that the shear strength can be easily estimated. The diagonal measurement of shear deformation is a convenient method because it has less effect on deformation due to the direction of the grain.

Authors

Institutions

Publication Details

Journal
European Journal of Wood and Wood Products
Published
2025-06-30
DOI
https://doi.org/10.1007/s00107-025-02278-0
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of in-plane shear performance of CLT using the asymmetric four-point bending test method and detailed examination of the method

Ryo Inoue, Takuro Mori, Mohammed Mestar, Kaito Yamagata
1 citations
European Journal of Wood and Wood Products
Structural Load-Bearing Analysis
0.95
article

Evaluation of in-plane shear performance of CLT using the asymmetric four-point bending test method and detailed examination of the method

Ryo Inoue, Takuro Mori, Mohammed Mestar, Kaito Yamagata
article en
1 citations

Abstract

Abstract The use of cross-laminated timber (CLT) and laminated veneer lumber (LVL) in wooden structures including non-residential, tall and large buildings is increasing, even though they might be subjected to important horizontal forces. The asymmetric four-point bending test method, originally used for lumber and glulam, can be used to evaluate the in-plane shear performance of CLT. This test may have led to bending failure in the case of the CLT specimens. In this study, asymmetric four-point bending tests were conducted to evaluate appropriate shear strength and modulus. Span ratio of 0.5–1.0 is recommended for shear failure to occur as the latter is less affected by compression force. The shear strength exhibited a positive correlation with the ratio of the perpendicular layer, suggesting that the shear strength can be easily estimated. The diagonal measurement of shear deformation is a convenient method because it has less effect on deformation due to the direction of the grain.

European Journal of Wood and Wood ProductsVol. 83(4)
Hiroshima University (JP), Royal Military College of Canada (CA), Kumamoto University (JP)
Hiroshima University
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of in-plane shear performance of CLT using the asymmetric four-point bending test method and detailed examination of the method — Ryo Inoue, Takuro Mori, et al. · European Journal of Wood and Wood Products (2025) | TGRS Research Map | TGRS