A novel method of half-life determination for highly charged ions based on isochronous mass spectrometry*

Abstract The lifetime of the isomeric state in fully stripped 94 Ru 44+ ions has been measured using isochronous mass spectrometry (IMS) at the experimental Cooler Storage Ring (CSRe) of the Heavy Ion Research Facility in Lanzhou (HIRFL). Previously, the isomeric lifetime was determined by analyzing the decay time points of individual decay events. In this paper, we present a novel approach to determine the isomeric lifetime based on the survival time of ions obtained from IMS. The survival lifetimes of the ground and isomeric states of 94 Ru 44+ were measured to be s and s in the laboratory, respectively. Given that the ground state of 94 Ru 44+ has a natural lifetime of approximately 75 min, its survival lifetime in the experimental setup was predominantly determined by the beam-loss lifetime, including interactions with residual gas in the storage ring and carbon foil of the detector. In contrast, the survival lifetime of 94 m Ru 44+ was governed by its intrinsic nuclear lifetime and additional beam-loss effects. The nuclear decay lifetime of 94 m Ru 44+ was extracted through differential survival lifetime analysis between ground and isomeric states, under the assumption that the beam-loss lifetimes for both quantum systems are identical. Using this novel methodology, the lifetime measured in the laboratory frame was s. After relativistic time-dilation corrections, the corresponding rest-frame half-life was calculated to be s. This result demonstrates excellent consistency with previous experimental results, validating the reliability of the new method. This method is suitable for determining half-lives of highly charged ions in the range of several tens of microseconds to milliseconds using IMS.

Authors

Institutions

Publication Details

Journal
Chinese Physics C
Published
2025-06-29
DOI
https://doi.org/10.1088/1674-1137/ade959
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method of half-life determination for highly charged ions based on isochronous mass spectrometry*

X. Xu, Y. M. Xing, H. F. Li, Bushi 布什 Huang 黄 et al.
Chinese Physics C
Mass Spectrometry Techniques and Applications
article

A novel method of half-life determination for highly charged ions based on isochronous mass spectrometry*

X. Xu, Y. M. Xing, H. F. Li, Bushi 布什 Huang 黄, Tingwei 婷微 Peng 彭, Huaiqiang 怀强 Zhang 张, Jiankun 剑锟 Zhao 赵, Qi 奇 Zeng 曾, Xu 旭 Zhou 周
article en

Abstract

Abstract The lifetime of the isomeric state in fully stripped 94 Ru 44+ ions has been measured using isochronous mass spectrometry (IMS) at the experimental Cooler Storage Ring (CSRe) of the Heavy Ion Research Facility in Lanzhou (HIRFL). Previously, the isomeric lifetime was determined by analyzing the decay time points of individual decay events. In this paper, we present a novel approach to determine the isomeric lifetime based on the survival time of ions obtained from IMS. The survival lifetimes of the ground and isomeric states of 94 Ru 44+ were measured to be s and s in the laboratory, respectively. Given that the ground state of 94 Ru 44+ has a natural lifetime of approximately 75 min, its survival lifetime in the experimental setup was predominantly determined by the beam-loss lifetime, including interactions with residual gas in the storage ring and carbon foil of the detector. In contrast, the survival lifetime of 94 m Ru 44+ was governed by its intrinsic nuclear lifetime and additional beam-loss effects. The nuclear decay lifetime of 94 m Ru 44+ was extracted through differential survival lifetime analysis between ground and isomeric states, under the assumption that the beam-loss lifetimes for both quantum systems are identical. Using this novel methodology, the lifetime measured in the laboratory frame was s. After relativistic time-dilation corrections, the corresponding rest-frame half-life was calculated to be s. This result demonstrates excellent consistency with previous experimental results, validating the reliability of the new method. This method is suitable for determining half-lives of highly charged ions in the range of several tens of microseconds to milliseconds using IMS.

Chinese Physics CVol. 49(11)
Jiangxi University of Technology (CN), East China University of Technology (CN), Institute of Modern Physics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangxi Province
Openalex Percentile: Top 86%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.