Identifikasi Parameter Modal Model Bangunan Dua Lantai Menggunakan Metode Covariance-driven Stochastic Subspace Identification

The modal parameters identification is a crucial part for designing and monitoring of a structure. This research is aimed to identify natural frequency and damping ratio of a lab-scaled two-story building model as a structure-under-test (SUT). The identification applies an operational modal analysis (OMA) technique, leveraging an algorithm of covariance-driven stochastic subspace identification (SSI-Cov) within PyOMA2 libraries. The SUT is subjected to random excitations using pseudo random signals within 0.1-25 Hz frequency range. The acceleration responses were sampled at 7.5 ms rate for 1 minute at each floor. Consequently, two modes with frequencies 2.2384 Hz and 5.9220 Hz are successfully identified below 25 Hz. These two modes yield 0.0135 and 0.0069 of damping ratios, respectively. These findings are compared to those of other algorithms that demonstrated a satisfactory identification of natural frequencies. However, a significant difference emerges in the identified damping ratios, particularly with regard to the second mode.

Authors

Institutions

Publication Details

Journal
Jurnal Surya Teknika
Published
2025-06-28
DOI
https://doi.org/10.37859/jst.v12i1.9310
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifikasi Parameter Modal Model Bangunan Dua Lantai Menggunakan Metode Covariance-driven Stochastic Subspace Identification

Adriyan Adriyan
Jurnal Surya Teknika
Computer Science and Engineering
article

Identifikasi Parameter Modal Model Bangunan Dua Lantai Menggunakan Metode Covariance-driven Stochastic Subspace Identification

Adriyan Adriyan
article en

Abstract

The modal parameters identification is a crucial part for designing and monitoring of a structure. This research is aimed to identify natural frequency and damping ratio of a lab-scaled two-story building model as a structure-under-test (SUT). The identification applies an operational modal analysis (OMA) technique, leveraging an algorithm of covariance-driven stochastic subspace identification (SSI-Cov) within PyOMA2 libraries. The SUT is subjected to random excitations using pseudo random signals within 0.1-25 Hz frequency range. The acceleration responses were sampled at 7.5 ms rate for 1 minute at each floor. Consequently, two modes with frequencies 2.2384 Hz and 5.9220 Hz are successfully identified below 25 Hz. These two modes yield 0.0135 and 0.0069 of damping ratios, respectively. These findings are compared to those of other algorithms that demonstrated a satisfactory identification of natural frequencies. However, a significant difference emerges in the identified damping ratios, particularly with regard to the second mode.

Jurnal Surya TeknikaVol. 12(1)
Universitas Muhammadiyah Riau (ID)
Openalex Percentile: Top 93%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.