Root Cause Analysis of Performance Degradation for an XYZ Thermal Power Plant in Tanzania

Thermal power plants in Tanzania have been experiencing performance degradation, typically arising from component and subsystem failures, which contribute to power system instability and unreliability. This paper presents a case study of the root causes of performance degradation of an XYZ thermal power plant. The study was conducted by reviewing plant documentations, including maintenance and operational data logbooks, and by standardising the approach through the adoption of ISO 14224:2016 for maintenance and reliability data exchange. Data evaluation was carried out using principal component analysis and scree plot analytical techniques to enhance the depth and accuracy of root cause identification. Additionally, Pareto analysis was employed to determine the extent of the degradation. The findings revealed that plant performance degradation was primarily caused by local environmental factors (i.e. dust and air salinity) and operational practices at the plant level, including skills gap and non-adherence to recommended maintenance schedules. With regard to component and subsystem failure incidents, the majority were valve and ignition system failures, accounting for 11.5% and 10.9%, respectively. The main failure modes were external utility fluid leakage (ELU) and overheating (OHE), which accounted for 23.32% and 18.78%, respectively. Moreover, instead of the 34,848 hours planned for proactive maintenance activities based on Original Equipment Manufacturer (OEM) recommendations, the plant consumed 127,392 hours, with over 80% dedicated to reactive maintenance. In conclusion, timely and proactive maintenance, supported by knowledgeable and skilled personnel, is crucial in ensuring stability, reliability, and longevity of the XYZ thermal power plant.

Authors

Institutions

Publication Details

Journal
Tanzania Journal of Engineering and Technology
Published
2025-06-29
DOI
https://doi.org/10.52339/tjet.v44i2.1303
Primary Topic
Energy and Environment Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Root Cause Analysis of Performance Degradation for an XYZ Thermal Power Plant in Tanzania

Simon I. Marandu, Mariam Ally
Tanzania Journal of Engineering and Technology
Energy and Environment Impacts
article

Root Cause Analysis of Performance Degradation for an XYZ Thermal Power Plant in Tanzania

Simon I. Marandu, Mariam Ally
article en

Abstract

Thermal power plants in Tanzania have been experiencing performance degradation, typically arising from component and subsystem failures, which contribute to power system instability and unreliability. This paper presents a case study of the root causes of performance degradation of an XYZ thermal power plant. The study was conducted by reviewing plant documentations, including maintenance and operational data logbooks, and by standardising the approach through the adoption of ISO 14224:2016 for maintenance and reliability data exchange. Data evaluation was carried out using principal component analysis and scree plot analytical techniques to enhance the depth and accuracy of root cause identification. Additionally, Pareto analysis was employed to determine the extent of the degradation. The findings revealed that plant performance degradation was primarily caused by local environmental factors (i.e. dust and air salinity) and operational practices at the plant level, including skills gap and non-adherence to recommended maintenance schedules. With regard to component and subsystem failure incidents, the majority were valve and ignition system failures, accounting for 11.5% and 10.9%, respectively. The main failure modes were external utility fluid leakage (ELU) and overheating (OHE), which accounted for 23.32% and 18.78%, respectively. Moreover, instead of the 34,848 hours planned for proactive maintenance activities based on Original Equipment Manufacturer (OEM) recommendations, the plant consumed 127,392 hours, with over 80% dedicated to reactive maintenance. In conclusion, timely and proactive maintenance, supported by knowledgeable and skilled personnel, is crucial in ensuring stability, reliability, and longevity of the XYZ thermal power plant.

Tanzania Journal of Engineering and TechnologyVol. 44(2)
University of Dar es Salaam (TZ)
Openalex Percentile: Top 89%
Energy and Environment Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Root Cause Analysis of Performance Degradation for an XYZ Thermal Power Plant in Tanzania — Simon I. Marandu, Mariam Ally · Tanzania Journal of Engineering and Technology (2025) | TGRS Research Map | TGRS