To reduce the seismic response of small buildings, the authors propose a magnetically levitated foundation insulated from the ground by magnets and supported by a displacement control material. In this study, metal components were used to improve the levitation force and damping characteristics. A static loading test indicated that steel plates on the magnets increased the levitation force. Electromagnetic field analysis showed that a copper plate between the magnets acted as an eddy-current damper and could be represented by a Maxwell material. In addition, the seismic response of a magnetically levitated foundation was discussed based on a shaking table test and structural analysis.
Authors
- Takaharu NAKANO (ORCID: https://orcid.org/0000-0002-9492-7135)
- Hisatoshi KASHIWA
- Yuji MIYAMOTO (ORCID: https://orcid.org/0000-0003-0512-7505)
Institutions
- Fukui University of Technology (JP)
- The University of Osaka (JP)
Publication Details
- Journal
- Journal of Japan Association for Earthquake Engineering
- Published
- 2025-01-01
- DOI
- https://doi.org/10.5610/jaee.25.8_12
- Primary Topic
- Electric Motor Design and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00