Label-free Electrochemical Immunosensor for Ultrasensitive Detection of KLK4 Using Conjugated Polymer Modified Sensing Platform

In the present research, a label-free impedimetric kallikrein 4 (KLK4) biosensor was fabricated by using a low-cost and disposable indium tin oxide (ITO) electrode and utilized for KLK4 detection in human serum. The ITO electrode was modified first by spin-coating of epoxy-substituted poly(thiophene) (Poly(TEpx)) conjugated polymer and thence anti-KLK4 antibody immobilization via the epoxy ends on the polymer. The specific interaction between the anti-KLK4 antibody present on the working electrode surface and the KLK4 antigen caused increases in the impedimetric response, and the KLK4 antigen was determined in a linear concentration range from 0.025 to 12.5 pg/mL with a detection limit of 7.78 fg/mL. Furthermore, the developed biosensor had acceptable repeatability and reproducibility, long storage stability, and high selectivity to KLK4 antigen. The applicability of the immunosensor was tested in human serum samples and satisfactory results were obtained.

Authors

Institutions

Publication Details

Journal
Hacettepe Journal of Biology and Chemistry
Published
2025-06-29
DOI
https://doi.org/10.15671/hjbc.1633456
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Label-free Electrochemical Immunosensor for Ultrasensitive Detection of KLK4 Using Conjugated Polymer Modified Sensing Platform

Elif Burcu Aydın
Hacettepe Journal of Biology and Chemistry
Advanced biosensing and bioanalysis techniques
article

Label-free Electrochemical Immunosensor for Ultrasensitive Detection of KLK4 Using Conjugated Polymer Modified Sensing Platform

Elif Burcu Aydın
article en

Abstract

In the present research, a label-free impedimetric kallikrein 4 (KLK4) biosensor was fabricated by using a low-cost and disposable indium tin oxide (ITO) electrode and utilized for KLK4 detection in human serum. The ITO electrode was modified first by spin-coating of epoxy-substituted poly(thiophene) (Poly(TEpx)) conjugated polymer and thence anti-KLK4 antibody immobilization via the epoxy ends on the polymer. The specific interaction between the anti-KLK4 antibody present on the working electrode surface and the KLK4 antigen caused increases in the impedimetric response, and the KLK4 antigen was determined in a linear concentration range from 0.025 to 12.5 pg/mL with a detection limit of 7.78 fg/mL. Furthermore, the developed biosensor had acceptable repeatability and reproducibility, long storage stability, and high selectivity to KLK4 antigen. The applicability of the immunosensor was tested in human serum samples and satisfactory results were obtained.

Hacettepe Journal of Biology and ChemistryVol. 53(3)
Tekirdağ Namık Kemal University (TR)
Openalex Percentile: Top 86%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.