Design and performance evaluation of magnetic hyperthermia instrument with embedded PI control

Hyperthermia is a non-invasive localized heating technique that has proven to be an efficient cancer treatment method. Hyperthermia therapy needs precise temperature control to ensure delivery of the proper thermal dose, causing minimum damage to the neighboring healthy tissues. This work reports the indigenous development of a custom-designed hyperthermia instrument. An advanced RISC machine (ARM)-based embedded closed-loop proportional-integral (PI) controller is developed for controlling the temperature. As per the applied methodology, the DC bias of a Mazzilli oscillator-based half-bridge inverter is controlled through the controller. The PI controller reads the hyperthermia system temperature using an infrared (IR) radiation thermometer and generates an analog output accordingly. This, in turn, changes the amplitude of the alternating magnetic field (AMF), thus controlling the temperature of the magnetic nanoparticles (MNPs). Its potential has been explored for <i>in vitro</i> hyperthermia studies. <i>In vitro</i> experiments have been carried out successfully with the custom-designed heater and controller assembly utilizing commercial non-invasive temperature measurement with a standard deviation of about 0.3°C and overshoot within the hyperthermia temperature range (3°C). The developed system has also obtained a satisfactory value of specific absorption rate (SAR). This paper infers the feasibility of the indigenously developed circuit and the related controller for hyperthermia therapy and preclinical studies. This system can be used for clinical applications with suitable customizations.

Authors

Institutions

Publication Details

Journal
Electromagnetic Biology and Medicine
Published
2025-06-29
DOI
https://doi.org/10.1080/15368378.2025.2524547
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance evaluation of magnetic hyperthermia instrument with embedded PI control

Mou Chatterjee, Sandip Pal
Electromagnetic Biology and Medicine
Electrical and Bioimpedance Tomography
article

Design and performance evaluation of magnetic hyperthermia instrument with embedded PI control

Mou Chatterjee, Sandip Pal
article en

Abstract

Hyperthermia is a non-invasive localized heating technique that has proven to be an efficient cancer treatment method. Hyperthermia therapy needs precise temperature control to ensure delivery of the proper thermal dose, causing minimum damage to the neighboring healthy tissues. This work reports the indigenous development of a custom-designed hyperthermia instrument. An advanced RISC machine (ARM)-based embedded closed-loop proportional-integral (PI) controller is developed for controlling the temperature. As per the applied methodology, the DC bias of a Mazzilli oscillator-based half-bridge inverter is controlled through the controller. The PI controller reads the hyperthermia system temperature using an infrared (IR) radiation thermometer and generates an analog output accordingly. This, in turn, changes the amplitude of the alternating magnetic field (AMF), thus controlling the temperature of the magnetic nanoparticles (MNPs). Its potential has been explored for <i>in vitro</i> hyperthermia studies. <i>In vitro</i> experiments have been carried out successfully with the custom-designed heater and controller assembly utilizing commercial non-invasive temperature measurement with a standard deviation of about 0.3°C and overshoot within the hyperthermia temperature range (3°C). The developed system has also obtained a satisfactory value of specific absorption rate (SAR). This paper infers the feasibility of the indigenously developed circuit and the related controller for hyperthermia therapy and preclinical studies. This system can be used for clinical applications with suitable customizations.

Electromagnetic Biology and MedicineVol. 44(4)
Variable Energy Cyclotron Centre (IN), Homi Bhabha National Institute (IN)
Affordable and clean energy
Openalex Percentile: Top 87%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and performance evaluation of magnetic hyperthermia instrument with embedded PI control — Mou Chatterjee, Sandip Pal · Electromagnetic Biology and Medicine (2025) | TGRS Research Map | TGRS