Additional Value of SPECT/CT Imaging to $${}^{\rm 99m}$$Tc-DTPA Dynamic Renal Scintigraphy in the Diagnosis of Patients with Different Nephro-urological Conditions

Dynamic renal scintigraphy with 99m Technetium diethylenetriaminepentaacetic acid (99mTc-DTPA) is a generally used imaging technique for evaluating renal function of patients with various nephro-urological conditions. However, the application of SPECT/CT is not regularly performed as a part of the study. The aim of the study was to evaluate the added value of SPECT/CT imaging to dynamic renal scintigraphy with 99m Tc-DTPA. Thirty-eight patients – 23 females (60.5%) and 15 males (39.5%), aged 16–83 years (mean: 55.4, standard deviation: 18.76) underwent dynamic nephroscintigraphy with subsequent SPECT/CT. The CT scan was performed with a low dose protocol. A dose of 185 MBq (5 mCi) 99m Tc-DTPA was administered intravenously. Our analysis demonstrated impaired relative renal function in various degrees of left kidney in 21 patients (55.3%) and of right kidney in 17 patients (44.7%). SPECT/CT maging revealed the specific cause, responsible for the renal dysfunction in the cases. The hybrid imaging demonstrated calculosis in 11 patients, urological cancer in 6 patients, postoperative strictures of ureter in five patients, external compression of ureter from ovarian cyst in one patient and compression of ureter due to nephroptosis in one patient as a possible obstructive cause. In 14 patients congenital renal anomalies were the identified causes of impaired renal function – hypoplastic kidney in five patients, duplex kidney in three patients, multiple cortical cysts in three patients, aberrant vessel obstructing the pyelo-ureteral segment in two patients and horseshoe kidney in one patient. The combination of conventional 99m Tc-DTPA dynamic renal scintigraphy with subsequent SPECT/CT could provide not only functional but also anatomical information of the urinary tract, especially in the valuation of obstructive uropathies and congenital renal abnormalities that can change the clinical management.

Authors

Institutions

Publication Details

Journal
Proceedings of the Bulgarian Academy of Sciences
Published
2025-06-29
DOI
https://doi.org/10.7546/crabs.2025.06.16
Primary Topic
Medical Imaging and Pathology Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Additional Value of SPECT/CT Imaging to $${}^{\rm 99m}$$Tc-DTPA Dynamic Renal Scintigraphy in the Diagnosis of Patients with Different Nephro-urological Conditions

Bozhil Robev, Milena Dimcheva, Ognyan Gatsev, Iliya Saltirov et al.
Proceedings of the Bulgarian Academy of Sciences
Medical Imaging and Pathology Studies
article

Additional Value of SPECT/CT Imaging to $${}^{\rm 99m}$$Tc-DTPA Dynamic Renal Scintigraphy in the Diagnosis of Patients with Different Nephro-urological Conditions

Bozhil Robev, Milena Dimcheva, Ognyan Gatsev, Iliya Saltirov, Sonya Sergieva, Teodor Sofiyanski
article en

Abstract

Dynamic renal scintigraphy with 99m Technetium diethylenetriaminepentaacetic acid (99mTc-DTPA) is a generally used imaging technique for evaluating renal function of patients with various nephro-urological conditions. However, the application of SPECT/CT is not regularly performed as a part of the study. The aim of the study was to evaluate the added value of SPECT/CT imaging to dynamic renal scintigraphy with 99m Tc-DTPA. Thirty-eight patients – 23 females (60.5%) and 15 males (39.5%), aged 16–83 years (mean: 55.4, standard deviation: 18.76) underwent dynamic nephroscintigraphy with subsequent SPECT/CT. The CT scan was performed with a low dose protocol. A dose of 185 MBq (5 mCi) 99m Tc-DTPA was administered intravenously. Our analysis demonstrated impaired relative renal function in various degrees of left kidney in 21 patients (55.3%) and of right kidney in 17 patients (44.7%). SPECT/CT maging revealed the specific cause, responsible for the renal dysfunction in the cases. The hybrid imaging demonstrated calculosis in 11 patients, urological cancer in 6 patients, postoperative strictures of ureter in five patients, external compression of ureter from ovarian cyst in one patient and compression of ureter due to nephroptosis in one patient as a possible obstructive cause. In 14 patients congenital renal anomalies were the identified causes of impaired renal function – hypoplastic kidney in five patients, duplex kidney in three patients, multiple cortical cysts in three patients, aberrant vessel obstructing the pyelo-ureteral segment in two patients and horseshoe kidney in one patient. The combination of conventional 99m Tc-DTPA dynamic renal scintigraphy with subsequent SPECT/CT could provide not only functional but also anatomical information of the urinary tract, especially in the valuation of obstructive uropathies and congenital renal abnormalities that can change the clinical management.

Proceedings of the Bulgarian Academy of SciencesVol. 78(6)
University Hospital St. Ivan Rilski (BG), Military Medical Academy (BG)
Openalex Percentile: Top 75%
Medical Imaging and Pathology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.