Breaking Metal and Bone - Multiple Consecutive TKA and DFR Failures in a Cyclist: A Case Report

Background: This is the first reported case, to our knowledge, of progressive implant failure in a professional cyclist due to internal tibial rotation following varus correction osteotomy, aggravated by sport-specific mechanics.It emphasizes the necessity of rotational assessment and activity modification in high-performance patients, offering novel insights into longterm failure mechanisms. Case presentation:A professional cyclist underwent an elective distraction osteotomy in 1997 to correct varus malalignment, resulting in severe internal rotation deformity of the distal tibia.The patient experienced five additional surgeries in 16 years follow-up due to progressive complications, including fractures of the femur and implant components.High-intensity cycling with clipless pedals exacerbated the rotational misalignment, subjecting implants to unanticipated forces. Conclusion:This underscores the importance of preoperative assessment for rotational deformities and postoperative activity modifications in high-demand athletes.The interaction between biomechanical misalignment and repetitive cycling motion highlights a rare mechanism of implant failure, providing insight into optimizing outcomes.

Publication Details

Journal
Journal of Surgery
Published
2025-06-21
DOI
https://doi.org/10.29011/2575-9760.011354
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breaking Metal and Bone - Multiple Consecutive TKA and DFR Failures in a Cyclist: A Case Report

Journal of Surgery
Orthopaedic implants and arthroplasty
article

Breaking Metal and Bone - Multiple Consecutive TKA and DFR Failures in a Cyclist: A Case Report

article en

Abstract

Background: This is the first reported case, to our knowledge, of progressive implant failure in a professional cyclist due to internal tibial rotation following varus correction osteotomy, aggravated by sport-specific mechanics.It emphasizes the necessity of rotational assessment and activity modification in high-performance patients, offering novel insights into longterm failure mechanisms. Case presentation:A professional cyclist underwent an elective distraction osteotomy in 1997 to correct varus malalignment, resulting in severe internal rotation deformity of the distal tibia.The patient experienced five additional surgeries in 16 years follow-up due to progressive complications, including fractures of the femur and implant components.High-intensity cycling with clipless pedals exacerbated the rotational misalignment, subjecting implants to unanticipated forces. Conclusion:This underscores the importance of preoperative assessment for rotational deformities and postoperative activity modifications in high-demand athletes.The interaction between biomechanical misalignment and repetitive cycling motion highlights a rare mechanism of implant failure, providing insight into optimizing outcomes.

Journal of SurgeryVol. 10(8)
Openalex Percentile: Top 74%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Breaking Metal and Bone - Multiple Consecutive TKA and DFR Failures in a Cyclist: A Case Report · Journal of Surgery (2025) | TGRS Research Map | TGRS