Dynamic Facial Dimensions in Design of Respirator: A Pilot Study

To involves dynamic facial movement into anthropometry, enhancing facial product design like respirator, this pilot study explored the dynamic dimensions and variations in facial dimensions under different movements in Chinses population. Using 3dMDface™ System, facial data were collected from 16 participants performing 9 movements that are required in respirator fitting test. This study manually selected 21 landmarks and calculated the Euclidean distances for 12 dimensions that related to the respirator design. Results revealed that longitudinal facial dimensions exhibited the largest variations, with facial length ranging from 116.0 mm to 192.4 mm (variation of 76.4 mm). In contrast, frontal dimensions showed smaller variations. Minimal variations were observed in inner upper face. Open mouth, grimacing and cough resulted in the greatest changes in facial dimensions. These findings highlight the importance of considering dynamic facial changes when designing masks or respirators, particularly by incorporating flexible features to accommodate facial elongation caused by jaw movements

Authors

Publication Details

Journal
AHFE international
Published
2025-01-01
DOI
https://doi.org/10.54941/ahfe1006112
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Facial Dimensions in Design of Respirator: A Pilot Study

Yuqian Wang, Haoyang Li, Yan Luximon
AHFE international
Ergonomics and Musculoskeletal Disorders
article

Dynamic Facial Dimensions in Design of Respirator: A Pilot Study

Yuqian Wang, Haoyang Li, Yan Luximon
article en

Abstract

To involves dynamic facial movement into anthropometry, enhancing facial product design like respirator, this pilot study explored the dynamic dimensions and variations in facial dimensions under different movements in Chinses population. Using 3dMDface™ System, facial data were collected from 16 participants performing 9 movements that are required in respirator fitting test. This study manually selected 21 landmarks and calculated the Euclidean distances for 12 dimensions that related to the respirator design. Results revealed that longitudinal facial dimensions exhibited the largest variations, with facial length ranging from 116.0 mm to 192.4 mm (variation of 76.4 mm). In contrast, frontal dimensions showed smaller variations. Minimal variations were observed in inner upper face. Open mouth, grimacing and cough resulted in the greatest changes in facial dimensions. These findings highlight the importance of considering dynamic facial changes when designing masks or respirators, particularly by incorporating flexible features to accommodate facial elongation caused by jaw movements

AHFE internationalVol. 166
Openalex Percentile: Top 83%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.