Vibration Exposure During Neonatal Patient Transport by Ground and Air Ambulance

Neonatal transport is often necessary when newborn patients require specialized medical care. In Ontario, Canada, a standardized Neonatal Patient Transport System (NPTS) is used to ensure consistency and interoperability across healthcare facilities. Whether transport is conducted via ground ambulance, fixed-wing, or rotary-wing air ambulances, the transport system and patient are subjected to unique, and often high, levels of vibration. Vibration is transmitted throughout the NPTS and interface systems such that the patients may experience a different ride quality than transport team members, pilots, or drivers. We have investigated the vibration amplitudes and spectra from 1-150 Hz at multiple locations (floor, NPTS, pilot/driver floor, and pilot/driver seat) within four different vehicles used for neonatal transportation in Ontario (one ground ambulance, one helicopter, and two fixed-wing aircraft). Kinematics were used to evaluate locations where sensors were not present during data collection. A low-frequency range of 1-20 Hz was used for comparison of measured and predicted results, to reduce noise in kinematic acceleration evaluation while focusing on the range of human body resonance. The largest amplitude vibrations were measured in the vertical direction in all vehicles, with the ground ambulance acceleration being greatest. Amplification of ground vehicle motion to the patient location was present across much of frequency range of interest, although the highest transmissibility occurred in the helicopter vertical direction at 10 Hz. The vibration in the air ambulances was heavily dominated by the rotor or propeller frequency, while in the ground ambulance it was more significant at low frequencies related to vehicle suspension. Differing response spectra suggest efforts to improve ride quality for patients may need to be tailored to the vehicle type, in order to prevent patient exposure to high amplitude vibration.

Authors

Publication Details

Journal
AHFE international
Published
2025-01-01
DOI
https://doi.org/10.54941/ahfe1006507
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibration Exposure During Neonatal Patient Transport by Ground and Air Ambulance

Andrew Law, Stephanie Redpath, Keely Gibb, Robert Langlois et al.
AHFE international
Noise Effects and Management
article

Vibration Exposure During Neonatal Patient Transport by Ground and Air Ambulance

Andrew Law, Stephanie Redpath, Keely Gibb, Robert Langlois, Andrew Ibey, Adrian D. C. Chan, Kim Greenwood, James R. Green, Eric Yu Hai Chen, Patrick Kehoe, Michael Avarello, Eleanor Gerson, Jean Ngoie
article en

Abstract

Neonatal transport is often necessary when newborn patients require specialized medical care. In Ontario, Canada, a standardized Neonatal Patient Transport System (NPTS) is used to ensure consistency and interoperability across healthcare facilities. Whether transport is conducted via ground ambulance, fixed-wing, or rotary-wing air ambulances, the transport system and patient are subjected to unique, and often high, levels of vibration. Vibration is transmitted throughout the NPTS and interface systems such that the patients may experience a different ride quality than transport team members, pilots, or drivers. We have investigated the vibration amplitudes and spectra from 1-150 Hz at multiple locations (floor, NPTS, pilot/driver floor, and pilot/driver seat) within four different vehicles used for neonatal transportation in Ontario (one ground ambulance, one helicopter, and two fixed-wing aircraft). Kinematics were used to evaluate locations where sensors were not present during data collection. A low-frequency range of 1-20 Hz was used for comparison of measured and predicted results, to reduce noise in kinematic acceleration evaluation while focusing on the range of human body resonance. The largest amplitude vibrations were measured in the vertical direction in all vehicles, with the ground ambulance acceleration being greatest. Amplification of ground vehicle motion to the patient location was present across much of frequency range of interest, although the highest transmissibility occurred in the helicopter vertical direction at 10 Hz. The vibration in the air ambulances was heavily dominated by the rotor or propeller frequency, while in the ground ambulance it was more significant at low frequencies related to vehicle suspension. Differing response spectra suggest efforts to improve ride quality for patients may need to be tailored to the vehicle type, in order to prevent patient exposure to high amplitude vibration.

AHFE internationalVol. 186
Openalex Percentile: Top 80%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.