Underground Three-Phase Power Transmission Line

Purpose: To consider a design and technological solution for reactive power compensation in a cable line. Firstly, to reduce power losses and, secondly, to increase the reliability of the power supply system. Methods: The method of analytical review of the advantages and disadvantages of underground cable transmission lines was employed; the calculation and analytical research was carried out using the theory of long lines. Results: The calculations for the three-phase power supply system parameters were conducted at varying interphase distances. The calculation results have demonstrated the capacitive nature of the input resistance complex in the idle mode and the dependence of the cable line capacitance on the interphase distance. Practical significance: The research results emphasize the advantages of using underground three-phase power transmission lines and justify the application of the proposed design.

Authors

Institutions

Publication Details

Journal
Bulletin of scientific research results
Published
2025-06-27
DOI
https://doi.org/10.20295/2223-9987-2025-2-49-56
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Underground Three-Phase Power Transmission Line

M. V. Shevlyugin, Veronika Varicheva, B. Dudin, Tamerlan Siukaev et al.
Bulletin of scientific research results
High-Voltage Power Transmission Systems
article

Underground Three-Phase Power Transmission Line

M. V. Shevlyugin, Veronika Varicheva, B. Dudin, Tamerlan Siukaev, Yuriy Ben'yash
article en

Abstract

Purpose: To consider a design and technological solution for reactive power compensation in a cable line. Firstly, to reduce power losses and, secondly, to increase the reliability of the power supply system. Methods: The method of analytical review of the advantages and disadvantages of underground cable transmission lines was employed; the calculation and analytical research was carried out using the theory of long lines. Results: The calculations for the three-phase power supply system parameters were conducted at varying interphase distances. The calculation results have demonstrated the capacitive nature of the input resistance complex in the idle mode and the dependence of the cable line capacitance on the interphase distance. Practical significance: The research results emphasize the advantages of using underground three-phase power transmission lines and justify the application of the proposed design.

Bulletin of scientific research resultsVol. 2025(2)
Russian University of Transport (RU)
Openalex Percentile: Top 87%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Underground Three-Phase Power Transmission Line — M. V. Shevlyugin, Veronika Varicheva, et al. · Bulletin of scientific research results (2025) | TGRS Research Map | TGRS