Respiratory Monitoring Device Based on Heterogeneously Integrated Highly Thermosensitive and Fast Response Nanosensors

In this work, we present a novel wearable respiratory monitoring device based on a heterogeneously integrated highly thermosensitive and fast-response nanosensor with a flexible substrate. The sensor is designed based on the ultralow thermal capacitance concept, and the fabricated sensor has a dynamic temperature resolution of 0.016 °C and a time response of 20 μs in laser pulse heating tests and a response time of 10.3 ms in water drop experiments. The device has been integrated with a microcontroller unit with wireless function and micro SD card for controlling data acquisition, transmission, and storage. The power consumption of the sensor is only 125 μW so that an 8 h dynamic monitoring is achieved by using a 100 mAh rechargeable battery. The whole device is miniaturized with a small footprint area of 10.9 cm<sup>2</sup> and a weight of 10.8 g. Acquired data with wavelet transform analysis successfully detected breathing diseases, such as apnea and tachypnea. Furthermore, the temperature variation in breathing is recorded, which provides extra information for a potential disease diagnosis.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-06-27
DOI
https://doi.org/10.1021/acssensors.5c01145
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Respiratory Monitoring Device Based on Heterogeneously Integrated Highly Thermosensitive and Fast Response Nanosensors

Junguo Xu, Jie Li, Zhengwu Zhu, Huiming Wu et al.
ACS Sensors
Advanced Sensor and Energy Harvesting Materials
article

Respiratory Monitoring Device Based on Heterogeneously Integrated Highly Thermosensitive and Fast Response Nanosensors

Junguo Xu, Jie Li, Zhengwu Zhu, Huiming Wu, S.L. Ou
article en

Abstract

In this work, we present a novel wearable respiratory monitoring device based on a heterogeneously integrated highly thermosensitive and fast-response nanosensor with a flexible substrate. The sensor is designed based on the ultralow thermal capacitance concept, and the fabricated sensor has a dynamic temperature resolution of 0.016 °C and a time response of 20 μs in laser pulse heating tests and a response time of 10.3 ms in water drop experiments. The device has been integrated with a microcontroller unit with wireless function and micro SD card for controlling data acquisition, transmission, and storage. The power consumption of the sensor is only 125 μW so that an 8 h dynamic monitoring is achieved by using a 100 mAh rechargeable battery. The whole device is miniaturized with a small footprint area of 10.9 cm<sup>2</sup> and a weight of 10.8 g. Acquired data with wavelet transform analysis successfully detected breathing diseases, such as apnea and tachypnea. Furthermore, the temperature variation in breathing is recorded, which provides extra information for a potential disease diagnosis.

ACS SensorsVol. 10(7)
Shenzhen University (CN)
National Natural Science Foundation of China
Clean water and sanitation
Openalex Percentile: Top 86%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Respiratory Monitoring Device Based on Heterogeneously Integrated Highly Thermosensitive and Fast Response Nanosensors — Junguo Xu, Jie Li, et al. · ACS Sensors (2025) | TGRS Research Map | TGRS