Detection of 5 GHz photons using Al Josephson junctions at 0.7 K

We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).

Authors

Institutions

Publication Details

Journal
Academia quantum.
Published
2025-06-27
DOI
https://doi.org/10.20935/acadquant7780
Citations
1
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of 5 GHz photons using Al Josephson junctions at 0.7 K

E. Il’ichev, A. L. Pankratov, L. S. Revin, Anna V. Gordeeva et al.
1 citations
Academia quantum.
Superconducting and THz Device Technology
1.15
article

Detection of 5 GHz photons using Al Josephson junctions at 0.7 K

E. Il’ichev, A. L. Pankratov, L. S. Revin, Anna V. Gordeeva, Dmitry A. Ladeynov, A. V. Chiginev, Sergey A. Razov
article en
1 citations

Abstract

We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).

Academia quantum.Vol. 2(2)
Institute for Physics of Microstructures (RU)
Openalex Percentile: Top 18%
Superconducting and THz Device Technology
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.