Fault interruption scheme for HVDC systems using GaN-HEMT and VCB

Power electronics switching devices played an important role in high-voltage DC circuit breaker development. Timely isolation of faulty portions of an HVDC transmission line from a healthy system is a basic requirement for a fault interruption. In this scenario, the integration of hybrid DC circuit breakers (HDCCBs) with wideband-gap semiconductor devices enables the effective management of high power, currents, and voltages. The SiC-MESFET and the GaN-HEMT are commonly used wideband-gap-based semiconductor devices. This paper introduces a fault interruption scheme for HVDC power systems, featuring the advancement of a hybrid DC circuit breaker. The proposed HDCCB design consists of two parts, one part is based on a VCB as a mechanical circuit breaker, and the second part involves electronic switches for fault interruption. The electronic switches are designed through the combination of GaN and HEMT to achieve fast switching to achieve rapid interruption of fault current. The system model is implemented through a Simulink model to perform a comparative analysis between the presented and existing protection topologies. Current commutation is achieved through the attainment of artificial zero current crossing to interrupt the DC fault. GaN-HEMT emerges as a more reliable and fast switching element compared to other electronic switches like Sic-MESFET as validated by the presented simulative results. The presented model shows better fault-clearing times of 2.2 ms and 2 ms for experimental parameters of (500 kV and 9kA) and (100 kV and 10kA), respectively. This fault-clearing time shows an improvement of 52.38% and 50% compared to the SiC-MESFET-based electronic switches used by the existing mechanisms. The outcomes of the proposed design are evaluated in terms of fault current, commutated current, and voltage across the commutated capacitor.

Authors

Institutions

Publication Details

Journal
Journal of Power Electronics
Published
2025-06-27
DOI
https://doi.org/10.1007/s43236-025-01089-z
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault interruption scheme for HVDC systems using GaN-HEMT and VCB

Shadman Saqlain Rahman, Muhammad Zeeshan Babar, Ali Raza, Muhammad Umair Shahid et al.
Journal of Power Electronics
HVDC Systems and Fault Protection
article

Fault interruption scheme for HVDC systems using GaN-HEMT and VCB

Shadman Saqlain Rahman, Muhammad Zeeshan Babar, Ali Raza, Muhammad Umair Shahid, Hamid Gulzar, Zahid Gulzar
article en

Abstract

Power electronics switching devices played an important role in high-voltage DC circuit breaker development. Timely isolation of faulty portions of an HVDC transmission line from a healthy system is a basic requirement for a fault interruption. In this scenario, the integration of hybrid DC circuit breakers (HDCCBs) with wideband-gap semiconductor devices enables the effective management of high power, currents, and voltages. The SiC-MESFET and the GaN-HEMT are commonly used wideband-gap-based semiconductor devices. This paper introduces a fault interruption scheme for HVDC power systems, featuring the advancement of a hybrid DC circuit breaker. The proposed HDCCB design consists of two parts, one part is based on a VCB as a mechanical circuit breaker, and the second part involves electronic switches for fault interruption. The electronic switches are designed through the combination of GaN and HEMT to achieve fast switching to achieve rapid interruption of fault current. The system model is implemented through a Simulink model to perform a comparative analysis between the presented and existing protection topologies. Current commutation is achieved through the attainment of artificial zero current crossing to interrupt the DC fault. GaN-HEMT emerges as a more reliable and fast switching element compared to other electronic switches like Sic-MESFET as validated by the presented simulative results. The presented model shows better fault-clearing times of 2.2 ms and 2 ms for experimental parameters of (500 kV and 9kA) and (100 kV and 10kA), respectively. This fault-clearing time shows an improvement of 52.38% and 50% compared to the SiC-MESFET-based electronic switches used by the existing mechanisms. The outcomes of the proposed design are evaluated in terms of fault current, commutated current, and voltage across the commutated capacitor.

Journal of Power ElectronicsVol. 26(2)
Heriot-Watt University (GB), Heriot-Watt University Malaysia (MY), University of Jeddah (SA), Khwaja Fareed University of Engineering and Information Technology (PK), Xi’an Jiaotong-Liverpool University (CN)
UK Research and Innovation
Openalex Percentile: Top 87%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.