Sensitivity, Specificity, and Interrater Reliability in the use of Computed Tomography as an Alternative to Dual X-ray Absorptiometry to Detect Osteoporosis and Osteopenia

Osteoporosis and osteopenia are one of the significant public health problems due to related low bone mineral density (BMD) and increased risk of fracture.Dual X-Ray Absorptiometry (DXA) is considered the gold standard for BMD assessment but is limited in availability and cannot assess bone microachitecture.This study assessed the diagnostic performance of Computed Tomography (CT) against DXA based on sensitivity, specificity and interrater reliability.This prospective study was done over 12 months in a tertiary health care hospital in Chennai which included 128 adult patients who underwent routine CT Abdomen and Pelvis for unrelated conditions.CT-derived Hounsfield Unit (HU) measurements were compared with T-scores from DXA. Sensitivity, Specificity and interrater reliability (Intraclass Correlation Coefficient, ICC) were calculated.Statistical methods included Pearson correlation and linear regression analysis.CT had a sensitivity of 0.88 and specificity of 0.92 for identifying osteoporosis, while DXA had a sensitivity of 0.85 and specificity of 0.90 when compared to CT.For osteopenia, CT was also more sensitive (0.78) and specific (0.85) than DXA (0.75 and 0.80, respectively) The interrater reliability of radiologists interpreting CT scans was strong, with intraclass correlation coefficient (ICC) of 0.92 for osteoporosis and 0.85 for osteopenia.A significant positive correlation (r = 0.75, p < 0.05) was found between HU values and BMDCT provides a reliable alternative to DXA for pathologic identification of osteoporosis and osteopenia, with high sensitivity, specificity and reproducibility.Opportunistic supplementation of HU values during routine CT scans is easy to perform in practice, and provides a tool for detecting individuals at high risk for metabolic bone disease.

Publication Details

Journal
Texila international journal of public health
Published
2025-06-27
DOI
https://doi.org/10.21522/tijph.2013.se.25.02.art008
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity, Specificity, and Interrater Reliability in the use of Computed Tomography as an Alternative to Dual X-ray Absorptiometry to Detect Osteoporosis and Osteopenia

Texila international journal of public health
Bone health and osteoporosis research
article

Sensitivity, Specificity, and Interrater Reliability in the use of Computed Tomography as an Alternative to Dual X-ray Absorptiometry to Detect Osteoporosis and Osteopenia

article en

Abstract

Osteoporosis and osteopenia are one of the significant public health problems due to related low bone mineral density (BMD) and increased risk of fracture.Dual X-Ray Absorptiometry (DXA) is considered the gold standard for BMD assessment but is limited in availability and cannot assess bone microachitecture.This study assessed the diagnostic performance of Computed Tomography (CT) against DXA based on sensitivity, specificity and interrater reliability.This prospective study was done over 12 months in a tertiary health care hospital in Chennai which included 128 adult patients who underwent routine CT Abdomen and Pelvis for unrelated conditions.CT-derived Hounsfield Unit (HU) measurements were compared with T-scores from DXA. Sensitivity, Specificity and interrater reliability (Intraclass Correlation Coefficient, ICC) were calculated.Statistical methods included Pearson correlation and linear regression analysis.CT had a sensitivity of 0.88 and specificity of 0.92 for identifying osteoporosis, while DXA had a sensitivity of 0.85 and specificity of 0.90 when compared to CT.For osteopenia, CT was also more sensitive (0.78) and specific (0.85) than DXA (0.75 and 0.80, respectively) The interrater reliability of radiologists interpreting CT scans was strong, with intraclass correlation coefficient (ICC) of 0.92 for osteoporosis and 0.85 for osteopenia.A significant positive correlation (r = 0.75, p < 0.05) was found between HU values and BMDCT provides a reliable alternative to DXA for pathologic identification of osteoporosis and osteopenia, with high sensitivity, specificity and reproducibility.Opportunistic supplementation of HU values during routine CT scans is easy to perform in practice, and provides a tool for detecting individuals at high risk for metabolic bone disease.

Texila international journal of public healthVol. 25(2)
Openalex Percentile: Top 80%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensitivity, Specificity, and Interrater Reliability in the use of Computed Tomography as an Alternative to Dual X-ray Absorptiometry to Detect Osteoporosis and Osteopenia · Texila international journal of public health (2025) | TGRS Research Map | TGRS