A case series of plug-based closure of peri-device leak after left atrial appendage occlusion
Peri-device leak (PDL) following left atrial appendage occlusion (LAAO) is particularly problematic in patients with both high thromboembolic and bleeding risk. We present a case series of three patients with atrial fibrillation and high bleeding risk. All three patients underwent LAAO with a Watchman™ and were found to have PDL on follow-up imaging. All three patients underwent successful PDL closure with an Amplatzer™ duct occluder II device with no complications noted. These cases demonstrate that PDL closure can be safely and effectively performed via a plug-based approach. Imaging is critical in determining candidacy for and method of PDL closure. • A plug-based approach can safely and effectively address PDL following LAAO. • Imaging is key in diagnosis, pre-procedural planning, and guiding successful closure. • Further study of device durability and long-term outcomes is needed.
Authors
- Nina Shyama Appareddy
- Gabriel Areoye
- Derar Albashaireh (ORCID: https://orcid.org/0000-0002-9983-9169)
- Suhaib El Khatib
- Bhavith Aruni
- Divyanshi Sood
- Shan Tandon
- Kathleen Brown (ORCID: https://orcid.org/0000-0002-5714-9434)
- George Gibson
- William Charles Stout
Institutions
- Colorado State University Pueblo (US)
Publication Details
- Journal
- Cardiovascular Revascularization Medicine Interesting Cases
- Published
- 2025-06-27
- DOI
- https://doi.org/10.1016/j.crmic.2025.100087
- Primary Topic
- Atrial Fibrillation Management and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00