Experimental Study on Adaptability of Electrical, Acoustic, and Optical Detection Methods for Metal Particles in GIL

Metal particles in GIL tend to move under electric field, reducing insulation reliability. This paper conducted partial discharge tests using a 252 kV gas-insulated busbar. The pulse current method, built-in UHF sensor, external UHF sensor, ultrasonic sensor, and photon counting sensor were employed to measure partial discharge characteristics of block, sheet, wire, and powder like metal particles. The results showed that the photon counting sensor and the built-in UHF sensor outperform the conventional PD detection method. The photon counting sensor had higher sensitivity to small-size and moving metal particles. The built-in UHF sensor has higher sensitivity to larger metal particles at low voltage levels. This study investigated the applicability of different detection methods for various metal particles, providing technical reference for online monitoring of metal particles in GIL devices.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11040346
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Adaptability of Electrical, Acoustic, and Optical Detection Methods for Metal Particles in GIL

Weiqi Qin, Xianhao Fan, Jiaying He, Tianyuan Zhang et al.
Non-Destructive Testing Techniques
article

Experimental Study on Adaptability of Electrical, Acoustic, and Optical Detection Methods for Metal Particles in GIL

Weiqi Qin, Xianhao Fan, Jiaying He, Tianyuan Zhang, Weiguo Li, Chuanyang Li, Changhong Zhang
article en

Abstract

Metal particles in GIL tend to move under electric field, reducing insulation reliability. This paper conducted partial discharge tests using a 252 kV gas-insulated busbar. The pulse current method, built-in UHF sensor, external UHF sensor, ultrasonic sensor, and photon counting sensor were employed to measure partial discharge characteristics of block, sheet, wire, and powder like metal particles. The results showed that the photon counting sensor and the built-in UHF sensor outperform the conventional PD detection method. The photon counting sensor had higher sensitivity to small-size and moving metal particles. The built-in UHF sensor has higher sensitivity to larger metal particles at low voltage levels. This study investigated the applicability of different detection methods for various metal particles, providing technical reference for online monitoring of metal particles in GIL devices.

China University of Geosciences (Beijing) (CN), China Southern Power Grid (China) (CN), Tsinghua University (CN)
National Natural Science Foundation of China - State Grid Corporation Joint Fund for Smart Grid
Openalex Percentile: Top 85%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.