High-Frequency Oscillation Analysis and Suppression Method for PV Power Generation System Equipped with Grid-Forming SVG

The high-frequency oscillation (HFO) occurred in the photovoltaic (PV) power generation station equipped with grid-forming (GFM) static var generator (SVG) is threatening the reliability of power system. This kind of HFO is generated by the interaction of negative resistance characteristic GFM, PV branch and inductive grid, while the existing analysis ignored the impact of the GFM SVG. To analyze the impact of GFM SVG on this kind of HFO occurring in PV power generation station equipped with GFM SVG, this paper establishes the PV power generation system's impedance model. Then, the impact of key GFM SVG parameters on the power generation system's high-frequency impedance characteristics is discussed. Further, to damp the HFO, an impedance reshaping strategy for GFM SVG based on attaching an additional current feedback control is proposed. The additional control can provide damping for the whole system so that the HFO can be suppressed. Finally, simulation results verify the stability impact analysis and the efficacy of the suppression strategy.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11040454
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Frequency Oscillation Analysis and Suppression Method for PV Power Generation System Equipped with Grid-Forming SVG

Xiaojuan Zhu, Kai Liao, Bo Pang, Pan Jiang et al.
Power Systems and Renewable Energy
article

High-Frequency Oscillation Analysis and Suppression Method for PV Power Generation System Equipped with Grid-Forming SVG

Xiaojuan Zhu, Kai Liao, Bo Pang, Pan Jiang, Zhiyuan He, Jianwei Yang
article en

Abstract

The high-frequency oscillation (HFO) occurred in the photovoltaic (PV) power generation station equipped with grid-forming (GFM) static var generator (SVG) is threatening the reliability of power system. This kind of HFO is generated by the interaction of negative resistance characteristic GFM, PV branch and inductive grid, while the existing analysis ignored the impact of the GFM SVG. To analyze the impact of GFM SVG on this kind of HFO occurring in PV power generation station equipped with GFM SVG, this paper establishes the PV power generation system's impedance model. Then, the impact of key GFM SVG parameters on the power generation system's high-frequency impedance characteristics is discussed. Further, to damp the HFO, an impedance reshaping strategy for GFM SVG based on attaching an additional current feedback control is proposed. The additional control can provide damping for the whole system so that the HFO can be suppressed. Finally, simulation results verify the stability impact analysis and the efficacy of the suppression strategy.

Southwest Jiaotong University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 85%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.