Error Analysis of Power System Simulation Based on Shifted- Frequency Electromagnetic Transient Model

The “dual-high” attributes of modern power systems place more stringent demands on the precision and effectiveness of electromagnetic transient simulations. The shifted-frequency electromagnetic transient simulation approach offers the advantage of larger time steps while maintaining accuracy, thereby significantly enhancing computational efficiency. How-ever, methodologies for error analysis specifically tailored to the shifted-frequency electromagnetic transient model are still underdeveloped. This paper introduces a novel error analysis technique for power system simulation grounded in the shifted-frequency electromagnetic transient model. It leverages port impedance characteristics to conduct error analysis and inves-tigates the impact of both shifted frequency and time step on simulation accuracy, making it well-suited for multi-partition hybrid simulation contexts. Finally, a case study is presented to demonstrate that the proposed method can offer a sound basis for parameter selection.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041183
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Error Analysis of Power System Simulation Based on Shifted- Frequency Electromagnetic Transient Model

Ligang Zhao, Tannan Xiao, Xiaoshan Wu, Yinsheng Su et al.
High-Voltage Power Transmission Systems
article

Error Analysis of Power System Simulation Based on Shifted- Frequency Electromagnetic Transient Model

Ligang Zhao, Tannan Xiao, Xiaoshan Wu, Yinsheng Su, Haoyuan Zhang, Ying Chen
article en

Abstract

The “dual-high” attributes of modern power systems place more stringent demands on the precision and effectiveness of electromagnetic transient simulations. The shifted-frequency electromagnetic transient simulation approach offers the advantage of larger time steps while maintaining accuracy, thereby significantly enhancing computational efficiency. How-ever, methodologies for error analysis specifically tailored to the shifted-frequency electromagnetic transient model are still underdeveloped. This paper introduces a novel error analysis technique for power system simulation grounded in the shifted-frequency electromagnetic transient model. It leverages port impedance characteristics to conduct error analysis and inves-tigates the impact of both shifted frequency and time step on simulation accuracy, making it well-suited for multi-partition hybrid simulation contexts. Finally, a case study is presented to demonstrate that the proposed method can offer a sound basis for parameter selection.

China Southern Power Grid (China) (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Error Analysis of Power System Simulation Based on Shifted- Frequency Electromagnetic Transient Model — Ligang Zhao, Tannan Xiao, et al. · (2025) | TGRS Research Map | TGRS