A Bilateral Impedance-Emulating Control of PWM Rectifier under Unbalanced Grids

The dc-link voltage oscillation is a direct reflection of the performance degradation caused by the unbalanced power grid in a three-phase voltage-source rectifier. A bilateral impedance-emulating control method is presented in this paper to solve this issue. The equivalent circuit model elucidates that VSR is characterized by emulated impedance on both sides under the proposed control scheme, providing a lucid and insightful physical interpretation. The bilateral impedanceemulating control provides the following features: 1) The elimination of grid voltage sensor; 2) Robustness to circuit parameters; 3) Easy to implement, as it only requires the design of a proportional-integral controller and two emulated RLC resonant circuits. In conclusion, the proposed control approach is straightforward, robust, and economical. Experimental results demonstrate its effectiveness and strong performance.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11040237
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Bilateral Impedance-Emulating Control of PWM Rectifier under Unbalanced Grids

Jianheng Lin, Mei Su, Wenjing Xiong, Weihao Yuan et al.
Microgrid Control and Optimization
article

A Bilateral Impedance-Emulating Control of PWM Rectifier under Unbalanced Grids

Jianheng Lin, Mei Su, Wenjing Xiong, Weihao Yuan, Yao Sun
article en

Abstract

The dc-link voltage oscillation is a direct reflection of the performance degradation caused by the unbalanced power grid in a three-phase voltage-source rectifier. A bilateral impedance-emulating control method is presented in this paper to solve this issue. The equivalent circuit model elucidates that VSR is characterized by emulated impedance on both sides under the proposed control scheme, providing a lucid and insightful physical interpretation. The bilateral impedanceemulating control provides the following features: 1) The elimination of grid voltage sensor; 2) Robustness to circuit parameters; 3) Easy to implement, as it only requires the design of a proportional-integral controller and two emulated RLC resonant circuits. In conclusion, the proposed control approach is straightforward, robust, and economical. Experimental results demonstrate its effectiveness and strong performance.

Central South University (CN)
Climate action
Openalex Percentile: Top 83%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.