Classification of Power Quality Disturbance with Synchrosqueezing and Vision Transformer

The rapid expansion of renewable energy sources (RES) in modern power systems has increased the occurrence of power quality disturbances (PQDs), affecting system performance. This paper introduces a novel approach combining Fourier Synchrosqueezing Transform (FSST) for time-frequency representation (TFR) with Vision Transformer (ViT) for classifying PQDs. By incorporating global characteristics, the ViT model increases classification accuracy, while GradCAM visualization improves interpretability. Experiments on synthetic datasets with single-type signal disturbances validate the proposed approach, showcasing superior performance in metrics compared to traditional methods. With a 99.73% accuracy rate, the proposed approach shows promise for precise classification and efficient power quality event monitoring.

Authors

Institutions

Publication Details

Published
2025-04-24
DOI
https://doi.org/10.1109/kpec65465.2025.11045008
Citations
1
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Classification of Power Quality Disturbance with Synchrosqueezing and Vision Transformer

Rahul Satheesh, R. Sunitha, K G Sreshtamol
1 citations
Advanced Algorithms and Applications
1.21
article

Classification of Power Quality Disturbance with Synchrosqueezing and Vision Transformer

Rahul Satheesh, R. Sunitha, K G Sreshtamol
article en
1 citations

Abstract

The rapid expansion of renewable energy sources (RES) in modern power systems has increased the occurrence of power quality disturbances (PQDs), affecting system performance. This paper introduces a novel approach combining Fourier Synchrosqueezing Transform (FSST) for time-frequency representation (TFR) with Vision Transformer (ViT) for classifying PQDs. By incorporating global characteristics, the ViT model increases classification accuracy, while GradCAM visualization improves interpretability. Experiments on synthetic datasets with single-type signal disturbances validate the proposed approach, showcasing superior performance in metrics compared to traditional methods. With a 99.73% accuracy rate, the proposed approach shows promise for precise classification and efficient power quality event monitoring.

National Institute of Technology Calicut (IN), Massachusetts Institute of Technology (US), Amrita Vishwa Vidyapeetham (IN)
Affordable and clean energy
Openalex Percentile: Top 20%
Advanced Algorithms and Applications
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.