Data-Driven Voltage Stability Assessment for Power Systems with Renewable Energy Integration

This paper proposes a static voltage assessment index system based on natural perturbations, leveraging the Wide Area Measurement System (WAMS) and building upon the mathematically rigorous foundations of reactive power-voltage sensitivity and bifurcation theory. Reactive power-voltage sensitivity is calculated using least squares fitting, and a weighted average algorithm is applied to statistically analyze sensitivity results over time, enhancing the accuracy and reliability of the fitted sensitivities. An IEEE benchmark system incorporating a wind farm is implemented in a numerical simulation platform. Time-domain simulations generate synchronized response data, allowing for comparison of sensitivity fitting results with actual reactive power margin under various operating conditions, thus validating the effectiveness of the proposed static voltage security assessment method.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/nesp65198.2025.11040631
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-Driven Voltage Stability Assessment for Power Systems with Renewable Energy Integration

Haifeng Zhang, Xiangyu Lv, Guanqun Zhuang, Shuyu Zhou et al.
Power System Optimization and Stability
article

Data-Driven Voltage Stability Assessment for Power Systems with Renewable Energy Integration

Haifeng Zhang, Xiangyu Lv, Guanqun Zhuang, Shuyu Zhou, Baoju Li, Jiajun Zhang
article en

Abstract

This paper proposes a static voltage assessment index system based on natural perturbations, leveraging the Wide Area Measurement System (WAMS) and building upon the mathematically rigorous foundations of reactive power-voltage sensitivity and bifurcation theory. Reactive power-voltage sensitivity is calculated using least squares fitting, and a weighted average algorithm is applied to statistically analyze sensitivity results over time, enhancing the accuracy and reliability of the fitted sensitivities. An IEEE benchmark system incorporating a wind farm is implemented in a numerical simulation platform. Time-domain simulations generate synchronized response data, allowing for comparison of sensitivity fitting results with actual reactive power margin under various operating conditions, thus validating the effectiveness of the proposed static voltage security assessment method.

Jilin Electric Power Research Institute (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.