Blocking Conditions and Optimization Suggestions for Fully Automatic Feeder Automation

Fully automatic feeder automation (FA) can achieve fault isolation and power restoration in non-fault areas within minutes, effectively enhancing the resilience of the power grid. To prevent abnormal operation of fully automatic FA, blocking conditions are typically established in the distribution master station. However, it has been proven in practice that some blocking conditions are overly conservative, potentially prolonging the customer interruption duration (CID) during fault. This paper elaborates on all the blocking conditions of fully automatic FA, with a particular focus on the impacts of terminal offline and discontinuous fault current signals. Through simulation in the dispatcher training system (DTS), it is demonstrated that these two blocking parameters fails to prevent misoperation of fully automatic FA, and shall only increase the number of CID. By removing these two blocking conditions, the success rate of fully automatic FA actions improved from 51% to 90%, as validated by operating data in Wuxi.

Authors

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041191
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blocking Conditions and Optimization Suggestions for Fully Automatic Feeder Automation

Guanghua Su, Xiaodong Liu, Yifan Sun, Yuan Gao et al.
Power Systems and Technologies
article

Blocking Conditions and Optimization Suggestions for Fully Automatic Feeder Automation

Guanghua Su, Xiaodong Liu, Yifan Sun, Yuan Gao, Li Chen, Zheng Zhen
article en

Abstract

Fully automatic feeder automation (FA) can achieve fault isolation and power restoration in non-fault areas within minutes, effectively enhancing the resilience of the power grid. To prevent abnormal operation of fully automatic FA, blocking conditions are typically established in the distribution master station. However, it has been proven in practice that some blocking conditions are overly conservative, potentially prolonging the customer interruption duration (CID) during fault. This paper elaborates on all the blocking conditions of fully automatic FA, with a particular focus on the impacts of terminal offline and discontinuous fault current signals. Through simulation in the dispatcher training system (DTS), it is demonstrated that these two blocking parameters fails to prevent misoperation of fully automatic FA, and shall only increase the number of CID. By removing these two blocking conditions, the success rate of fully automatic FA actions improved from 51% to 90%, as validated by operating data in Wuxi.

Openalex Percentile: Top 87%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.