QC-CNN: Highly Quantized Compressive CNN for Efficient Ventricular Arrhythmia Detection in Implantable Cardioverter Defibrillators

The Implantable Cardioverter Defibrillator (ICD) is a device designed to reduce the risk of Sudden Cardiac Death (SCD) by detecting life-threatening ventricular arrhythmias (VAs) through intracardiac electrograms (IEGMs). Ensuring accurate VA detection across diverse patient populations remains a challenge, as traditional ICDs either rely on manual tuning of patient-specific parameters or suffer from low detection accuracy. While machine learning models, particularly convolutional neural networks (CNNs), have demonstrated improved accuracy and flexibility, their large model size and high sampling frequency make them hard to be deployed in ICDs due to limited memory and energy capacity on ICDs. To address these constraints, we propose a compressive sensing (CS)-inspired CNN architecture that reduces model size by 50× and reduce the sample frequency by 25×. By reconstructing signals with fewer measurements and applying low-bit quantization, our model is optimized for efficient execution on analog domain frontend ADC. Experimental results show our model could use only 3% power consumption of the classic approach on ADC with no accuracy loss.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11043637
Primary Topic
Advancements in Semiconductor Devices and Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QC-CNN: Highly Quantized Compressive CNN for Efficient Ventricular Arrhythmia Detection in Implantable Cardioverter Defibrillators

Yiyu Shi, Xuan Zhang, Zhenge Jia, Weidong Cao et al.
Advancements in Semiconductor Devices and Circuit Design
article

QC-CNN: Highly Quantized Compressive CNN for Efficient Ventricular Arrhythmia Detection in Implantable Cardioverter Defibrillators

Yiyu Shi, Xuan Zhang, Zhenge Jia, Weidong Cao, Jian Gao, Zining Wang
article en

Abstract

The Implantable Cardioverter Defibrillator (ICD) is a device designed to reduce the risk of Sudden Cardiac Death (SCD) by detecting life-threatening ventricular arrhythmias (VAs) through intracardiac electrograms (IEGMs). Ensuring accurate VA detection across diverse patient populations remains a challenge, as traditional ICDs either rely on manual tuning of patient-specific parameters or suffer from low detection accuracy. While machine learning models, particularly convolutional neural networks (CNNs), have demonstrated improved accuracy and flexibility, their large model size and high sampling frequency make them hard to be deployed in ICDs due to limited memory and energy capacity on ICDs. To address these constraints, we propose a compressive sensing (CS)-inspired CNN architecture that reduces model size by 50× and reduce the sample frequency by 25×. By reconstructing signals with fewer measurements and applying low-bit quantization, our model is optimized for efficient execution on analog domain frontend ADC. Experimental results show our model could use only 3% power consumption of the classic approach on ADC with no accuracy loss.

University of Notre Dame (US), Northeastern University (US), George Washington University (US), Shandong University of Science and Technology (CN)
Good health and well-being
Openalex Percentile: Top 87%
Advancements in Semiconductor Devices and Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.