Research on BIPVT-Wastewater Source Heat Pump System for Bathroom Hot Water Supply

This study proposes a new BIPV/T-sewage source heat pump coupled energy supply scheme to address the high energy consumption problem of bathroom heating systems in universities in cold regions. Based on the measured data of a university bathroom in Shenyang, an integrated system was constructed, which includes a photovoltaic electric heating integrated roof, a layered thermal storage water tank, a sewage source heat pump, and an intelligent control device. Through TRNSYS dynamic simulation and multi-objective optimization using genetic algorithm, the system achieved an annual heating capacity of 216909 kWh and a solar energy contribution rate of 56% −85%. The research results show that after optimization, the COP of the system operation has been improved to 4.92, with a conventional energy substitution of 52.4 tons of standard coal compared to the traditional gas boiler scheme.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/nesp65198.2025.11040949
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on BIPVT-Wastewater Source Heat Pump System for Bathroom Hot Water Supply

Hao Hong, Shengnan Shi
Geothermal Energy Systems and Applications
article

Research on BIPVT-Wastewater Source Heat Pump System for Bathroom Hot Water Supply

Hao Hong, Shengnan Shi
article en

Abstract

This study proposes a new BIPV/T-sewage source heat pump coupled energy supply scheme to address the high energy consumption problem of bathroom heating systems in universities in cold regions. Based on the measured data of a university bathroom in Shenyang, an integrated system was constructed, which includes a photovoltaic electric heating integrated roof, a layered thermal storage water tank, a sewage source heat pump, and an intelligent control device. Through TRNSYS dynamic simulation and multi-objective optimization using genetic algorithm, the system achieved an annual heating capacity of 216909 kWh and a solar energy contribution rate of 56% −85%. The research results show that after optimization, the COP of the system operation has been improved to 4.92, with a conventional energy substitution of 52.4 tons of standard coal compared to the traditional gas boiler scheme.

Shenyang Jianzhu University (CN)
Clean water and sanitation
Openalex Percentile: Top 91%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.