Background Calibration for Mixed Mismatches in TIADC Using Taylor-Volterra-Series-Based Model
The linear and nonlinear mismatches in time-interleaved analog-to-digital converter (TIADC) both severely degrade the system’s performance. Calibration techniques play a crucial role in restoring TIADC’s optimal performance. However, existing techniques have application limitations in nonlinear modeling and exhibit one-sidedness in error detection, leading to overfitting. This paper proposes a new background calibration for mixed linear and nonlinear errors. A unified model with wide applicability is presented to characterize mixed error generation based on the Taylor and the Volterra series. Then the errors are calibrated by a high-precision algorithm which addresses the issues of high dimensional optimization and overfitting problems simultaneously. The proposed technique is verified with simulations in MATLAB and experiments in a 16-bit 4-channel 260MS/s board-level prototype, improving the SFDR from 35.5 dB to 73.3 dB with a dual-tone input at 67.6 MHz and 119.6 MHz.
Authors
- Song Wang (ORCID: https://orcid.org/0000-0001-8457-0390)
- Ziyu Guo (ORCID: https://orcid.org/0000-0002-4792-1398)
- Jun Han (ORCID: https://orcid.org/0000-0002-5245-0754)
- Xu Cheng (ORCID: https://orcid.org/0000-0002-0314-0178)
Institutions
- Fudan University (CN)
Publication Details
- Published
- 2025-05-25
- DOI
- https://doi.org/10.1109/iscas56072.2025.11044309
- Citations
- 2
- Primary Topic
- Analog and Mixed-Signal Circuit Design
- Type
- article
- Field-Weighted Citation Impact
- 1.35
Funders
- National Natural Science Foundation of China