Analysis of the Influence of Clock Asynchronism on Fault Location of T-Connected Transmission Lines

T-connected transmission lines are widely used because of their compact topology and low construction cost. However, the complex operating environment makes it easy to fail, so quick fault detection is essential for maintaining power system stability. However, The adoption of classic approaches two-terminal fault location method to T-connected transmission lines faces two problems: First, the complex propagation path leads to the existence of location dead zone near the T node, in fact, the clock synchronization error can compromise fault location accuracy Accordingly, a method is presented for identifying the fault branch based on the traveling wave head's polarity when the fault occurs near T node and analyzes the impact of clock asynchronism on fault identification and its compensation method. The simulation results of PSCAD/EMTDC show that he method accurately identifies fault branches when faults are located near T nodes. And transition resistors and effectively analyze the law of distance measurement error caused by clock asynchronism, which provides a theoretical basis for delay compensation of field distance measurement devices.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041445
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Influence of Clock Asynchronism on Fault Location of T-Connected Transmission Lines

Yanfeng Jia, Yuanyuan Zeng, Junfeng Song, Yanxun Guo et al.
Power Systems and Technologies
article

Analysis of the Influence of Clock Asynchronism on Fault Location of T-Connected Transmission Lines

Yanfeng Jia, Yuanyuan Zeng, Junfeng Song, Yanxun Guo, Xinzheng Yang
article en

Abstract

T-connected transmission lines are widely used because of their compact topology and low construction cost. However, the complex operating environment makes it easy to fail, so quick fault detection is essential for maintaining power system stability. However, The adoption of classic approaches two-terminal fault location method to T-connected transmission lines faces two problems: First, the complex propagation path leads to the existence of location dead zone near the T node, in fact, the clock synchronization error can compromise fault location accuracy Accordingly, a method is presented for identifying the fault branch based on the traveling wave head's polarity when the fault occurs near T node and analyzes the impact of clock asynchronism on fault identification and its compensation method. The simulation results of PSCAD/EMTDC show that he method accurately identifies fault branches when faults are located near T nodes. And transition resistors and effectively analyze the law of distance measurement error caused by clock asynchronism, which provides a theoretical basis for delay compensation of field distance measurement devices.

Zhengzhou University (CN)
State Grid Henan Electric Power Company
Sustainable cities and communities
Openalex Percentile: Top 87%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.