Analysis of the Correlation Between Multiple Interference Factors and the Measurement Error of CVT

The measurement accuracy of Capacitive Voltage Transformers (CVTs) plays a vital role in high-voltage electric energy metering systems and is a key factor in ensuring the reliability and stability of power system metering. Numerous factors, such as temperature, electric fields, and humidity, can influence CVT accuracy, potentially leading to measurement errors that affect overall system performance. Therefore, a systematic correlation analysis of these interference factors is necessary to clarify their mechanisms and impact levels. This study conducted an in-depth analysis using Pearson correlation analysis to evaluate the effects of external factors, including temperature, electric fields, and humidity, on CVT measurement errors such as ratio and angular errors. The results show that electric fields have the most significant impact on CVT measurement errors, requiring particular attention in design and application. These findings provide an important theoretical basis for monitoring and assessing CVT errors in high-voltage metering systems and offer scientific guidance for improving their performance.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041306
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Correlation Between Multiple Interference Factors and the Measurement Error of CVT

Lingyu Xia, Xixiu Wu, Shipu Wu, Jian Fang et al.
Engineering Applied Research
article

Analysis of the Correlation Between Multiple Interference Factors and the Measurement Error of CVT

Lingyu Xia, Xixiu Wu, Shipu Wu, Jian Fang, Jianghong Mo, Zong Shou Lin
article en

Abstract

The measurement accuracy of Capacitive Voltage Transformers (CVTs) plays a vital role in high-voltage electric energy metering systems and is a key factor in ensuring the reliability and stability of power system metering. Numerous factors, such as temperature, electric fields, and humidity, can influence CVT accuracy, potentially leading to measurement errors that affect overall system performance. Therefore, a systematic correlation analysis of these interference factors is necessary to clarify their mechanisms and impact levels. This study conducted an in-depth analysis using Pearson correlation analysis to evaluate the effects of external factors, including temperature, electric fields, and humidity, on CVT measurement errors such as ratio and angular errors. The results show that electric fields have the most significant impact on CVT measurement errors, requiring particular attention in design and application. These findings provide an important theoretical basis for monitoring and assessing CVT errors in high-voltage metering systems and offer scientific guidance for improving their performance.

North China Electric Power University (CN), Wuhan University of Technology (CN), Shanghai Electric (China) (CN), State Grid Hebei Electric Power Company, China Electric Power Research Institute
Openalex Percentile: Top 84%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.