Characterization of Harmonic Frequency Response of Capacitive Voltage Transformer

The harmonic frequency response characteristics of CVT are of great significance to the correction of its harmonic measurement error. Based on the basic structure of 500kV capacitive voltage transformer, an equivalent circuit model of industrial frequency and harmonic transmission is constructed, and the amplitude and phase frequency response curves of CVT are given. The influence of harmonic content and harmonic order on fundamental and harmonic frequency characteristics is studied. It is shown that the frequency response curve of CVT is not smooth due to the existence of obvious singular points, and the response characteristics of the frequency near the singular points deteriorate sharply. The order of harmonics and their content have basically no effect on the error transfer characteristics of the fundamental wave. When fundamental and multiple harmonics exist at the primary side at the same time, the influence of multiple harmonics on the ratio difference of each harmonic component can be basically negligible, but there is a certain impact on the diagonal difference.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/nesp65198.2025.11040830
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of Harmonic Frequency Response of Capacitive Voltage Transformer

Xiong Xiao, Can Xu, Bingyuan Tan, Chun Li et al.
Sensor Technology and Measurement Systems
article

Characterization of Harmonic Frequency Response of Capacitive Voltage Transformer

Xiong Xiao, Can Xu, Bingyuan Tan, Chun Li, Jixiang Liu, Wenhao Lu
article en

Abstract

The harmonic frequency response characteristics of CVT are of great significance to the correction of its harmonic measurement error. Based on the basic structure of 500kV capacitive voltage transformer, an equivalent circuit model of industrial frequency and harmonic transmission is constructed, and the amplitude and phase frequency response curves of CVT are given. The influence of harmonic content and harmonic order on fundamental and harmonic frequency characteristics is studied. It is shown that the frequency response curve of CVT is not smooth due to the existence of obvious singular points, and the response characteristics of the frequency near the singular points deteriorate sharply. The order of harmonics and their content have basically no effect on the error transfer characteristics of the fundamental wave. When fundamental and multiple harmonics exist at the primary side at the same time, the influence of multiple harmonics on the ratio difference of each harmonic component can be basically negligible, but there is a certain impact on the diagonal difference.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of Harmonic Frequency Response of Capacitive Voltage Transformer — Xiong Xiao, Can Xu, et al. · (2025) | TGRS Research Map | TGRS