Fault Ride-through Method for Dual-bridge Series Resonant Converter

The output-short-circuit (OSC) fault is a severe challenge faced by the dual-bridge series resonant converter (DBSRC). However, due to the uncertain state of the resonant cavity at the moment when the fault occurs, and the existence of residual energy that cannot be precisely controlled after current limiting, the initial state of the DBSRC during restart is uncontrollable, which will affect the working state of the DBSRC after restarting. This paper provides a fault ride-through method targeting the OSC fault in DBSRC. This method consists of four steps to achieve the detection, current limiting, location and clearance of the fault. Furthermore, the initial energy of the resonant cavity after current limiting and its influence on the fault ride-through process were quantitatively evaluated. A soft-start method has also been developed to determine the optimal phase-shift angle during fault localization. This approach can quickly restart the circuit within preset current threshold to establish fault criterion current. Finally, the simulation results demonstrate the efficacy of the proposed fault ride-through method.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041021
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Ride-through Method for Dual-bridge Series Resonant Converter

Zhuolan Li, Zonghui Sun, Yu Zhang, Zirui Wang
HVDC Systems and Fault Protection
article

Fault Ride-through Method for Dual-bridge Series Resonant Converter

Zhuolan Li, Zonghui Sun, Yu Zhang, Zirui Wang
article en

Abstract

The output-short-circuit (OSC) fault is a severe challenge faced by the dual-bridge series resonant converter (DBSRC). However, due to the uncertain state of the resonant cavity at the moment when the fault occurs, and the existence of residual energy that cannot be precisely controlled after current limiting, the initial state of the DBSRC during restart is uncontrollable, which will affect the working state of the DBSRC after restarting. This paper provides a fault ride-through method targeting the OSC fault in DBSRC. This method consists of four steps to achieve the detection, current limiting, location and clearance of the fault. Furthermore, the initial energy of the resonant cavity after current limiting and its influence on the fault ride-through process were quantitatively evaluated. A soft-start method has also been developed to determine the optimal phase-shift angle during fault localization. This approach can quickly restart the circuit within preset current threshold to establish fault criterion current. Finally, the simulation results demonstrate the efficacy of the proposed fault ride-through method.

Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 87%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault Ride-through Method for Dual-bridge Series Resonant Converter — Zhuolan Li, Zonghui Sun, et al. · (2025) | TGRS Research Map | TGRS