Quantitative Evaluation Method for Improving the Section Transmission Capacity Considering Embedded DC Access

This study develops a quantitative assessment methodology to determine the total transmission capability of AC/DC hybrid power systems with embedded DC links. The proposed approach systematically integrates critical operational constraints including equipment capacities, stability boundaries, and contingency response characteristics. By analyzing power flow sensitivity characteristics and employing line outage distribution factors under contingency conditions, the method enables precise evaluation of system-wide transmission capacity. Furthermore, an adaptive power distribution control strategy is formulated to maintain grid operational stability, featuring automatic DC power adjustment mechanisms that respond to operational mode variations and post-fault scenarios. The control scheme integrates seamlessly with existing grid management requirements. Finally, smulation tests conducted on practical power network models demonstrate the technical validity and operational effectiveness of both the evaluation methodology and control strategy.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041222
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Evaluation Method for Improving the Section Transmission Capacity Considering Embedded DC Access

Haijun Chang, Haifeng Li, Juan Wang, Tao Jin et al.
Engineering Applied Research
article

Quantitative Evaluation Method for Improving the Section Transmission Capacity Considering Embedded DC Access

Haijun Chang, Haifeng Li, Juan Wang, Tao Jin, Zhaowei Li, Hui Huang
article en

Abstract

This study develops a quantitative assessment methodology to determine the total transmission capability of AC/DC hybrid power systems with embedded DC links. The proposed approach systematically integrates critical operational constraints including equipment capacities, stability boundaries, and contingency response characteristics. By analyzing power flow sensitivity characteristics and employing line outage distribution factors under contingency conditions, the method enables precise evaluation of system-wide transmission capacity. Furthermore, an adaptive power distribution control strategy is formulated to maintain grid operational stability, featuring automatic DC power adjustment mechanisms that respond to operational mode variations and post-fault scenarios. The control scheme integrates seamlessly with existing grid management requirements. Finally, smulation tests conducted on practical power network models demonstrate the technical validity and operational effectiveness of both the evaluation methodology and control strategy.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.