Experimental Investigation of the Influence of Branch Busbar Length on VFTO Amplitude in Gas-Insulated Equipment

In recent years, with the rapid development of new power grid structures such as pumped storage power stations and high-voltage direct current transmission, ultra-high voltage (UHV) and extra-high voltage (EHV) equipment have experienced multiple insulation failures. The unclear failure mechanisms, prolonged repair durations, and significant economic losses pose a serious threat to the safe operation of the power grid. Very fast transient overvoltage (VFTO) caused by disconnector switching operations is often suspected to be a contributing factor to defect formation due to its high amplitude (up to 3 p.u.) and high frequency (up to 100 MHz). This paper presents an experimental study on VFTO measurements conducted at the Wuhan UHV AC test base. The maximum VFTO amplitude is significantly influenced by the length of the branch busbar. Specifically, the maximum VFTO values measured at Point 4 were 1.75 p.u., 1.88 p.u., and 2.23 p.u. for branch busbar lengths of 0 m, 3 m, and 9 m, respectively.

Authors

Institutions

Publication Details

Published
2025-04-15
DOI
https://doi.org/10.1109/acpee64358.2025.11041635
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of the Influence of Branch Busbar Length on VFTO Amplitude in Gas-Insulated Equipment

Hao Wang, Wei Wang
Engineering Applied Research
article

Experimental Investigation of the Influence of Branch Busbar Length on VFTO Amplitude in Gas-Insulated Equipment

Hao Wang, Wei Wang
article en

Abstract

In recent years, with the rapid development of new power grid structures such as pumped storage power stations and high-voltage direct current transmission, ultra-high voltage (UHV) and extra-high voltage (EHV) equipment have experienced multiple insulation failures. The unclear failure mechanisms, prolonged repair durations, and significant economic losses pose a serious threat to the safe operation of the power grid. Very fast transient overvoltage (VFTO) caused by disconnector switching operations is often suspected to be a contributing factor to defect formation due to its high amplitude (up to 3 p.u.) and high frequency (up to 100 MHz). This paper presents an experimental study on VFTO measurements conducted at the Wuhan UHV AC test base. The maximum VFTO amplitude is significantly influenced by the length of the branch busbar. Specifically, the maximum VFTO values measured at Point 4 were 1.75 p.u., 1.88 p.u., and 2.23 p.u. for branch busbar lengths of 0 m, 3 m, and 9 m, respectively.

North China Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Investigation of the Influence of Branch Busbar Length on VFTO Amplitude in Gas-Insulated Equipment — Hao Wang, Wei Wang · (2025) | TGRS Research Map | TGRS