CC/CV ZVS WPT system without any feedback from receiver to transmitter

In this paper, a WPT system that can switch between constant current (CC) and constant voltage (CV) in a single circuit is proposed. In the proposed WPT system, the CC and CV modes are achieved by varying the on-duty ratio of the buck converter. In addition, the proposed system also keeps the zero-voltage switching against coil misalignment and load variations without any information feedback from the rectifier to the inverter. This is because the load-independent behavior is built into the proposed system. The experimental results are consistent with the analytical predictions, which show the validity of the proposed circuit design strategy and the derived analytical expressions. Under rated conditions, the output power was 36.9 W and the power conversion efficiency was 86 % at the operating frequency of 6.78 MHz.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11044113
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CC/CV ZVS WPT system without any feedback from receiver to transmitter

Yutaro Komiyama, Hiroo Sekiya, Wenqi Zhu, Xiuqin Wei et al.
Power Line Communications and Noise
article

CC/CV ZVS WPT system without any feedback from receiver to transmitter

Yutaro Komiyama, Hiroo Sekiya, Wenqi Zhu, Xiuqin Wei, Ayano Komanaka, Akihiro Konishi, Kien Nguyen, Yinchen Xie, Jiaxin Yan
article en

Abstract

In this paper, a WPT system that can switch between constant current (CC) and constant voltage (CV) in a single circuit is proposed. In the proposed WPT system, the CC and CV modes are achieved by varying the on-duty ratio of the buck converter. In addition, the proposed system also keeps the zero-voltage switching against coil misalignment and load variations without any information feedback from the rectifier to the inverter. This is because the load-independent behavior is built into the proposed system. The experimental results are consistent with the analytical predictions, which show the validity of the proposed circuit design strategy and the derived analytical expressions. Under rated conditions, the output power was 36.9 W and the power conversion efficiency was 86 % at the operating frequency of 6.78 MHz.

Chiba University (JP), Tokyo University of Science (JP), Chiba Institute of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 87%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.