Optimized Hardware Architecture for Respiration Rate Classification using Quadratic SVM and mmWave Radar Sensor
In this paper, we propose an FPGA based system for non-contact monitoring of respiration rates (RR) using a mmWave frequency modulated continuous wave (FMCW) radar. The novel FPGA based hardware architecture presented in this paper classifies normal and abnormal RR with a Support Vector Machine (SVM) model using mmWave radar-based sensing. SVM with various kernels are evaluated in order to identify the most effective approach for respiratory rate (RR) classification. SVM with a quadratic polynomial kernel shows a high classification accuracy of 95%. While the accuracy was comparable to other kernels, the quadratic polynomial kernel achieved a substantial reduction in the number of support vectors and other parameters. This optimisation results in lower resource utilisation and power consumption, making it highly efficient for FPGA implementation.
Authors
- Mohd Wajid (ORCID: https://orcid.org/0000-0002-6932-6354)
- R. Shamim
- Abhishek Srivastava (ORCID: https://orcid.org/0000-0002-2418-6677)
- Mujeev Khan (ORCID: https://orcid.org/0009-0008-1606-9359)
Institutions
- Aligarh Muslim University (IN)
- Indian Institute of Technology Hyderabad (IN)
Publication Details
- Published
- 2025-05-25
- DOI
- https://doi.org/10.1109/iscas56072.2025.11043731
- Citations
- 1
- Primary Topic
- Sensor Technology and Measurement Systems
- Type
- article
- Field-Weighted Citation Impact
- 1.49