Compensation of Excess Loop Delay in Continuous-Time Incremental ∆Σ ADCs

Continuous-time (CT) Delta-Sigma (DS) ADCs are a popular choice for high resolution, medium bandwidth applications. A critical challenge is the excess-loop-delay (ELD) in the feedback path of the modulator, which causes performance degradation and instability. For free-running Delta-Sigma modulators (DSMs), performance can be fully recovered by adjusting the loop filter to restore the original noise transfer function (NTF) without ELD. For CT incremental Delta-Sigma (I-DS) ADCs, this has not been specifically investigated, but it is worth noting that the process of ELD compensation is slightly different. In this paper, we investigate the effect of ELD on I-DS ADCs and show that the performance cannot be fully recovered by NTF engineering as in the free-running case, but requires signal transfer function (STF) engineering as well. We also present solutions on how to engineer the STF and how to fully recover the performance even in the presence of ELD in CT I-DS ADCs.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11044169
Citations
1
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compensation of Excess Loop Delay in Continuous-Time Incremental ∆Σ ADCs

Maurits Ortmanns, Joachim Becker, Omar Ismail, Paul Kaesser
1 citations
Analog and Mixed-Signal Circuit Design
0.67
article

Compensation of Excess Loop Delay in Continuous-Time Incremental ∆Σ ADCs

Maurits Ortmanns, Joachim Becker, Omar Ismail, Paul Kaesser
article en
1 citations

Abstract

Continuous-time (CT) Delta-Sigma (DS) ADCs are a popular choice for high resolution, medium bandwidth applications. A critical challenge is the excess-loop-delay (ELD) in the feedback path of the modulator, which causes performance degradation and instability. For free-running Delta-Sigma modulators (DSMs), performance can be fully recovered by adjusting the loop filter to restore the original noise transfer function (NTF) without ELD. For CT incremental Delta-Sigma (I-DS) ADCs, this has not been specifically investigated, but it is worth noting that the process of ELD compensation is slightly different. In this paper, we investigate the effect of ELD on I-DS ADCs and show that the performance cannot be fully recovered by NTF engineering as in the free-running case, but requires signal transfer function (STF) engineering as well. We also present solutions on how to engineer the STF and how to fully recover the performance even in the presence of ELD in CT I-DS ADCs.

Universität Ulm (DE)
National Science Foundation
Openalex Percentile: Top 30%
Analog and Mixed-Signal Circuit Design
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.