A High-Density Transcranial Electrical Stimulation System on Chip with Real-Time Bio-Impedance Sensing

This paper presents a system on chip (SoC) designed for high-density transcranial electrical stimulation (HD-TES) with real-time bio-impedance sensing. Multiple chips can work collaboratively to generate arbitrary waveforms for HD-TES including temporal interference (TI) stimulation. This design implements a combined digital calibration and analog switch mechanism for common-mode voltage holding (CMVH), ensuring long-time safety of HD-TES. The SoC can perform impedance measurement (IM) through transcranial alternating current stimulation (tACs) allowing to monitor the biological impedance variations during tACs. To ensure the safety of current stimulation, switched-capacitor overcurrent protection (OCP) circuit is integrated. Measured results show that the SoC can apply arbitrary stimulation currents within the voltage range of ±13V. The amplitude range of the current is from - 2.5mA to 2.5mA with a 10 μA minimum step. The common-mode voltage of the electrode remains stable near 0V when operating in HD-TES mode. Impedance measurement error is less than 5% within the extensive range of 0.5kΩ to 500kΩ.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11043809
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Density Transcranial Electrical Stimulation System on Chip with Real-Time Bio-Impedance Sensing

Jianzheng Li, Yajie Qin, Jizong Yao, Shuai Yuan et al.
Neuroscience and Neural Engineering
article

A High-Density Transcranial Electrical Stimulation System on Chip with Real-Time Bio-Impedance Sensing

Jianzheng Li, Yajie Qin, Jizong Yao, Shuai Yuan, Yufei Liu
article en

Abstract

This paper presents a system on chip (SoC) designed for high-density transcranial electrical stimulation (HD-TES) with real-time bio-impedance sensing. Multiple chips can work collaboratively to generate arbitrary waveforms for HD-TES including temporal interference (TI) stimulation. This design implements a combined digital calibration and analog switch mechanism for common-mode voltage holding (CMVH), ensuring long-time safety of HD-TES. The SoC can perform impedance measurement (IM) through transcranial alternating current stimulation (tACs) allowing to monitor the biological impedance variations during tACs. To ensure the safety of current stimulation, switched-capacitor overcurrent protection (OCP) circuit is integrated. Measured results show that the SoC can apply arbitrary stimulation currents within the voltage range of ±13V. The amplitude range of the current is from - 2.5mA to 2.5mA with a 10 μA minimum step. The common-mode voltage of the electrode remains stable near 0V when operating in HD-TES mode. Impedance measurement error is less than 5% within the extensive range of 0.5kΩ to 500kΩ.

Fudan University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 84%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.